Literature DB >> 11505742

Microbial contamination of eye drops.

H Taşli1, G Coşar.   

Abstract

The microbial contamination of eye drops at the Eye Clinic was studied. In total, 92 eye drop bottles were examined. 43 bottles were opened and used and 49 were unopened and sealed. The contamination rate was found to be 10.2% in unopened bottles and 34.8% in opened bottles. The opened bottles had been used for two weeks. Six of the samples yielded coagulase-negative Staphylococci and nine samples yielded one or two different microorganisms. The contamination rate in bottles containing the preservative benzalkonium chloride was 34.4%. Among unopened eye drop bottles two samples yielded S. aureus, two coagulase-negative Staphylococci and one Bacillus spp.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11505742

Source DB:  PubMed          Journal:  Cent Eur J Public Health        ISSN: 1210-7778            Impact factor:   1.163


  7 in total

1.  Balancing antimicrobial efficacy and toxicity of currently available topical ophthalmic preservatives.

Authors:  Elmer Y Tu
Journal:  Saudi J Ophthalmol       Date:  2014-06-23

2.  Microbial contamination of preservative free eye drops in multiple application containers.

Authors:  M Q Rahman; D Tejwani; J A Wilson; I Butcher; K Ramaesh
Journal:  Br J Ophthalmol       Date:  2006-02       Impact factor: 4.638

3.  Antiglaucoma drugs: The role of preservative-free formulations.

Authors:  Alessandro Bagnis; Marina Papadia; Riccardo Scotto; Carlo E Traverso
Journal:  Saudi J Ophthalmol       Date:  2011-08-28

4.  [Preservatives in ophthalmology].

Authors:  E M Messmer
Journal:  Ophthalmologe       Date:  2012-11       Impact factor: 1.059

5.  Microbial contamination of glaucoma eyedrops used by patients compared with ocular medications used in the hospital.

Authors:  Barbara Teuchner; Julia Wagner; Nikolaos E Bechrakis; Dorothea Orth-Höller; Markus Nagl
Journal:  Medicine (Baltimore)       Date:  2015-02       Impact factor: 1.889

6.  Bacterial Contamination of Multi-dose Eye Drops at Ophthalmology Department, University of Gondar, Northwest Ethiopia.

Authors:  Asegedech Tsegaw; Asamere Tsegaw; Tefera Abula; Yared Assefa
Journal:  Middle East Afr J Ophthalmol       Date:  2017 Apr-Jun

7.  Microbial Cross-contamination in Multidose Eyedrops: The Impact of Instillation Angle and Bottle Geometry.

Authors:  Alexandre Xavier da Costa; Maria Cecilia Zorat Yu; Denise de Freitas; Priscila Cardoso Cristovam; Lauren C LaMonica; Vagner Rogerio Dos Santos; José Alvaro Pereira Gomes
Journal:  Transl Vis Sci Technol       Date:  2020-06-05       Impact factor: 3.283

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.