Literature DB >> 11503130

Wear debris from total hip arthroplasty presenting as an intrapelvic mass.

K H Mak1, T K Wong, N C Poddar.   

Abstract

A granulomatous reaction to the small particles worn off from an implanted prosthesis is a common complication in arthroplasty. The chronic inflammatory response to the wear debris from either the polyethylene or the metal components is thought to be responsible for osteolysis, implant loosening, and finally mechanical failure. Formation of an extra-articular granulomatous tissue mass is uncommon, however. We report a case of a huge granulomatous mass that presented as an intrapelvic tumor. The prosthesis was an Anatomical Medullary Locking (AML) hip arthroplasty with cementless fixation. The polyethylene insert was manufactured by ram extrusion and sterilized with gamma irradiation in air. Fragments of the insert were among the contents in the cystic mass together with black metallic debris. There was no loosening of the prosthesis, and the acetabulum floor was preserved.

Entities:  

Mesh:

Year:  2001        PMID: 11503130     DOI: 10.1054/arth.2001.23726

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  15 in total

Review 1.  Cystic lesion around the hip joint.

Authors:  Kiminori Yukata; Sho Nakai; Tomohiro Goto; Yuichi Ikeda; Yasunori Shimaoka; Issei Yamanaka; Koichi Sairyo; Jun-Ichi Hamawaki
Journal:  World J Orthop       Date:  2015-10-18

2.  Metal artifact reduction sequence MRI abnormalities occur in metal-on-polyethylene hips.

Authors:  Thomas K Fehring; Keith Fehring; Susan M Odum
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

Review 3.  Intra-abdominal and intra-pelvic complications following operations around the hip: causes and management-a review of the literature.

Authors:  Panagiotis P Anastasopoulos; Panagiotis Lepetsos; Andreas O Leonidou; Anastasios Gketsos; Eleftherios Tsiridis; George A Macheras
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-02-12

4.  Pseudotumor associated with cemented bipolar hemiarthroplasty: an unusual presentation as a granulomatous thigh mass.

Authors:  Tomohiro Goto; Kazuaki Mineta; Tomoya Takasago; Daisuke Hamada; Koichi Sairyo
Journal:  Skeletal Radiol       Date:  2015-06-23       Impact factor: 2.199

5.  Electron Microprobe Analysis and Tissue Reaction around Titanium Alloy Spinal Implants.

Authors:  Hee-Dong Kim; Ki-Soo Kim; Sung-Chan Ki; Yong-Soo Choi
Journal:  Asian Spine J       Date:  2007-06-30

6.  Metallosis with pseudotumour formation: Long-term complication following cementless total hip replacement in a dog.

Authors:  Nicola J Volstad; Susan L Schaefer; Laura A Snyder; Jeffrey B Meinen; Susannah J Sample
Journal:  Vet Comp Orthop Traumatol       Date:  2016-05-18       Impact factor: 1.358

7.  [MRI investigations in patients with problems due to metal-on-metal implants].

Authors:  T M Parsons; K Satchithananda; R Berbe; I A Siddiqui; E Robinson; A J Hart; A Hart
Journal:  Orthopade       Date:  2013-08       Impact factor: 1.087

8.  Particulate debris osteolysis simulating malignant tumor.

Authors:  Richard A Brand; J Lawrence Marsh
Journal:  Iowa Orthop J       Date:  2004

9.  Wear debris pseudotumor following total knee arthroplasty: a case report.

Authors:  Andreas F Mavrogenis; George N Nomikos; Vasileios I Sakellariou; George I Karaliotas; Panayiotis Kontovazenitis; Panayiotis J Papagelopoulos
Journal:  J Med Case Rep       Date:  2009-11-29

10.  Pre-surgical radiologic identification of peri-prosthetic osteolytic lesions around TKRs: a pre-clinical investigation of diagnostic accuracy.

Authors:  Timothy P Kurmis; Andrew P Kurmis; David G Campbell; John P Slavotinek
Journal:  J Orthop Surg Res       Date:  2008-10-03       Impact factor: 2.359

View more