Literature DB >> 11502705

Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease.

M S Wathen1, M O Sweeney, P J DeGroot, A J Stark, J L Koehler, M B Chisner, C Machado, W O Adkisson.   

Abstract

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) can terminate some ventricular tachycardias (VTs) painlessly with antitachycardia pacing (ATP). ATP has not routinely been applied for VT >188 bpm because of concerns about efficacy, risk of acceleration, and delay of definitive shock therapy. This prospective, multicenter study evaluated the efficacy of empirical ATP to terminate fast VT (FVT; >188 bpm). METHODS AND
RESULTS: Two hundred twenty coronary artery disease patients received ICDs for standard indications. Empirical, standardized therapy was programmed so that all FVT episodes (average cycle length [CL] 240 to 320 ms, 250 to 188 bpm) were treated with 2 ATP sequences (8-pulse burst pacing train at 88% of the FVT CL) before shock delivery. A total of 1100 episodes of spontaneous ventricular tachyarrhythmias occurred during a mean of 6.9+/-3.6 months of follow-up. Fifty-seven percent were classified as slow VT (CL>/=320 ms), 40% as FVT (240 ms</=CL<320 ms), and 3% as ventricular fibrillation (CL<240 ms). A total of 446 FVT episodes, mean CL=301+/-24 ms, occurred in 52 patients (median 2 episodes per patient). ATP terminated 396 FVT episodes (89%), with an adjusted efficacy of 77% (95% CI 68% to 83%). VT acceleration caused by ATP occurred in 10 FVT episodes (4%). FVT arrhythmic syncope occurred on 9 occasions (2%) in 4 patients.
CONCLUSIONS: FVT (CL<320 ms) is common in ICD patients. ATP can terminate 3 of 4 of these episodes with a low incidence of acceleration and syncope. ATP for FVT may safely reduce the morbidity of painful shocks.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11502705     DOI: 10.1161/hc3101.093906

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  46 in total

1.  The S1103Y cardiac sodium channel variant is associated with implantable cardioverter-defibrillator events in blacks with heart failure and reduced ejection fraction.

Authors:  Albert Y Sun; Jason I Koontz; Svati H Shah; Jonathan P Piccini; Kent R Nilsson; Damian Craig; Carol Haynes; Simon G Gregory; Patrick M Hranitzky; Geoffrey S Pitt
Journal:  Circ Cardiovasc Genet       Date:  2011-04-15

2.  Outcome of cardioverter-defibrillator implant in patients with arrhythmogenic right ventricular cardiomyopathy.

Authors:  Giuseppe Boriani; Paolo Artale; Mauro Biffi; Cristian Martignani; Lorenzo Frabetti; Cinzia Valzania; Igor Diemberger; Matteo Ziacchi; Matteo Bertini; Claudio Rapezzi; Mario Parlapiano; Angelo Branzi
Journal:  Heart Vessels       Date:  2007-05-21       Impact factor: 2.037

Review 3.  Subcutaneous implantable cardiac defibrillators: indications and limitations.

Authors:  Maria Grazia Bongiorni; Stefano Viani; Giulio Zucchelli; Andrea Di Cori; Luca Segreti; Luca Paperini; Dianora Levorato; Adriano Boem; Giulia Branchitta; Diana Andreini; Ezio Soldati
Journal:  Curr Heart Fail Rep       Date:  2015-02

Review 4.  The subcutaneous ICD-current evidence and challenges.

Authors:  Kiran Haresh Kumar Patel; Pier D Lambiase
Journal:  Cardiovasc Diagn Ther       Date:  2014-12

Review 5.  How to improve outcomes: should we put more emphasis on programming and medical care and less on patient selection?

Authors:  Laszlo Buga
Journal:  Heart Fail Rev       Date:  2012-11       Impact factor: 4.214

Review 6.  ICD programming to reduce shocks and improve outcomes.

Authors:  Valentina Kutyifa; Wojciech Zareba; Arthur J Moss
Journal:  Curr Cardiol Rep       Date:  2014       Impact factor: 2.931

7.  Reduction of the inappropriate ICD therapies by implementing a new fuzzy logic-based diagnostic algorithm.

Authors:  Michał Lewandowski; Andrzej Przybylski; Wiesław Kuźmicz; Hanna Szwed
Journal:  Ann Noninvasive Electrocardiol       Date:  2013-09       Impact factor: 1.468

Review 8.  Optimal tachycardia programming in ICDs : Recommendations in the post-MADIT-RIT era.

Authors:  Carsten W Israel; Tatsiana Burmistrava
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2016-09

9.  A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: the RELEVANT [Role of long dEtection window programming in patients with LEft VentriculAr dysfunction, Non-ischemic eTiology in primary prevention treated with a biventricular ICD] study.

Authors:  Maurizio Gasparini; Carlo Menozzi; Alessandro Proclemer; Maurizio Landolina; Severio Iacopino; Angelo Carboni; Ernesto Lombardo; François Regoli; Mauro Biffi; Valeria Burrone; Alessandra Denaro; Giuseppe Boriani
Journal:  Eur Heart J       Date:  2009-06-29       Impact factor: 29.983

10.  Prospective multicenter randomized trial of fast ventricular tachycardia termination by prolonged versus conventional anti-tachyarrhythmia burst pacing in implantable cardioverter-defibrillator patients-Atp DeliVery for pAiNless ICD thErapy (ADVANCE-D) Trial results.

Authors:  Massimo Santini; Maurizio Lunati; Pascal Defaye; Johann Mermi; Alessandro Proclemer; Silvia del Castillo-Arroys; Giulio Molon; Elisabetta Santi; Tiziana De Santo; Xavier Navarro; Axel Kloppe
Journal:  J Interv Card Electrophysiol       Date:  2010-01-20       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.