Literature DB >> 11502423

Slice acquisition order and blood oxygenation level dependent frequency content: an event-related functional magnetic resonance imaging study.

A L Paradis1, P F Van de Moortele, D Le Bihan, J B Poline.   

Abstract

Many event-related functional magnetic resonance imaging paradigms performed so far have been designed to study a limited part of the brain with high temporal resolution. However, event-related paradigms can be exploratory, therefore requiring whole brain scans and so repetition times (TR) of several seconds. For these large TR values, the slice acquisition order may have an important effect on the detection of event-related activation. Indeed, when the scanning is interleaved, the temporal delay between the acquisition of two contiguous slices can reach a few seconds. During this time, the subject is likely to move, and the haemodynamic response will vary significantly. In this case, the interpolation applied between contiguous slices for motion correction induces a temporal smoothing between voxels that are spatially close but temporally sampled a few seconds apart. This should modify the frequency structure of the response and may impair the detection of short events. We, therefore tested the effect of three acquisition schemes (sequential, sequential with gap and interleaved, INT) at two repetition times (TR=3 and 6 s on six and seven subjects, respectively) on activation detection and frequency content in a visual motion event-related paradigm. Unexpectedly, for large TR (6 s), results were found in favour of the INT acquisition scheme (P<0.05). For smaller TR, no strong bias could be found. Generally, intra-subject variability (across acquisition schemes) is found to be much smaller than inter-subject variability, confirming the importance of multi-subjects analyses. Our study also shows that important physiological information is carried by high frequency components that should not be filtered out.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11502423     DOI: 10.1007/bf02668157

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  9 in total

Review 1.  Event-related functional magnetic resonance imaging: modelling, inference and optimization.

Authors:  O Josephs; R N Henson
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-07-29       Impact factor: 6.237

2.  The effect of slice order and thickness on fMRI activation data using multislice echo-planar imaging.

Authors:  A M Howseman; S Grootoonk; D A Porter; J Ramdeen; A P Holmes; R Turner
Journal:  Neuroimage       Date:  1999-04       Impact factor: 6.556

3.  Functional MR imaging of visual and motor cortex stimulation at high temporal resolution using a FLASH technique on a standard 1.5 Tesla scanner.

Authors:  E Wiener; L R Schad; K T Baudendistel; M Essig; E Müller; W J Lorenz
Journal:  Magn Reson Imaging       Date:  1996       Impact factor: 2.546

4.  Analysis of fMRI time-series revisited--again.

Authors:  K J Worsley; K J Friston
Journal:  Neuroimage       Date:  1995-09       Impact factor: 6.556

5.  Empirical analyses of BOLD fMRI statistics. I. Spatially unsmoothed data collected under null-hypothesis conditions.

Authors:  E Zarahn; G K Aguirre; M D'Esposito
Journal:  Neuroimage       Date:  1997-04       Impact factor: 6.556

6.  Statistical methods of estimation and inference for functional MR image analysis.

Authors:  E Bullmore; M Brammer; S C Williams; S Rabe-Hesketh; N Janot; A David; J Mellers; R Howard; P Sham
Journal:  Magn Reson Med       Date:  1996-02       Impact factor: 4.668

7.  Improving functional imaging techniques: the dream of a single image for a single mental event.

Authors:  T J Grabowski; A R Damasio
Journal:  Proc Natl Acad Sci U S A       Date:  1996-12-10       Impact factor: 11.205

8.  Detection of cortical activation during averaged single trials of a cognitive task using functional magnetic resonance imaging.

Authors:  R L Buckner; P A Bandettini; K M O'Craven; R L Savoy; S E Petersen; M E Raichle; B R Rosen
Journal:  Proc Natl Acad Sci U S A       Date:  1996-12-10       Impact factor: 11.205

9.  Event-related functional MR imaging of visual cortex stimulation at high temporal resolution using a standard 1.5 T imager.

Authors:  L R Schad; E Wiener; K T Baudendistel; E Müller; W J Lorenz
Journal:  Magn Reson Imaging       Date:  1995       Impact factor: 2.546

  9 in total
  1 in total

1.  Atlas-based multichannel monitoring of functional MRI signals in real-time: automated approach.

Authors:  Jong-Hwan Lee; Heather M O'Leary; Hyunwook Park; Ferenc A Jolesz; Seung-Schik Yoo
Journal:  Hum Brain Mapp       Date:  2008-02       Impact factor: 5.038

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.