Literature DB >> 11501804

Observations of the proximal tibia in total knee arthroplasty.

D F Dalury1.   

Abstract

Relatively little has been written concerning the proximal tibia in total knee arthroplasty. Few authors have looked at landmarks and guidelines for tibial tray preparation and tibial tray orientation. The current study showed that a line drawn 1 mm medial to the medial border of the tibial tubercle and going through the midsulcus of the tibial spines (the midsulcus line) provided a reproducible landmark for the tibia, and when a perpendicular cut was made relative to this line, 46 of 50 knees were cut in appropriate alignment. In addition, it has been said that the tibial tray should be rotated externally to approximately the medial 1/3 of the tubercle to maximize function. The current study showed that when the tibia is allowed to float in a functional position relative to the femoral implant, the tibial external rotation was only 2 mm lateral from the medial age of the tibial tubercle; this is far less than the medial 1/3 of the tubercle and close to the starting point of the midsulcus line.

Mesh:

Year:  2001        PMID: 11501804     DOI: 10.1097/00003086-200108000-00021

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  25 in total

1.  Comparison of the tibiofemoral rotational alignment after mobile and fixed bearing total knee arthroplasty.

Authors:  Dongwook Kim; Sang Cheol Seong; Myung Chul Lee; Sahnghoon Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-06       Impact factor: 4.342

Review 2.  Rotational alignment of the tibial component in total knee arthroplasty.

Authors:  Pier Francesco Indelli; Angelo Graceffa; Massimiliano Marcucci; Andrea Baldini
Journal:  Ann Transl Med       Date:  2016-01

3.  Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error.

Authors:  Csaba Forster-Horvath; Valerie Kremo; Magdalena Müller-Gerbl; Andrej Maria Nowakowski
Journal:  Int Orthop       Date:  2015-07-09       Impact factor: 3.075

4.  Reliable and reproducible technique to mark center of ankle in total knee arthroplasty.

Authors:  Anshul Sobti; Shriji Maniar; Sameer Chaudhari; Vivek Shetty
Journal:  J Clin Orthop Trauma       Date:  2015-03-19

5.  Rotational alignment of the tibial component in total knee arthroplasty: the anterior tibial cortex is a reliable landmark.

Authors:  Andrea Baldini; Pier Francesco Indelli; Lapo DE Luca; Pierpaolo Cerulli Mariani; Massimiliano Marcucci
Journal:  Joints       Date:  2014-03-21

6.  Medial sixth of the patellar tendon at the tibial attachment is useful for the anterior reference in rotational alignment of the tibial component.

Authors:  Shinya Kawahara; Ken Okazaki; Shuichi Matsuda; Hiroaki Mitsuyasu; Hiroyuki Nakahara; Shigetoshi Okamoto; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-03-12       Impact factor: 4.342

7.  Is there a gold standard for TKA tibial component rotational alignment?

Authors:  Erin E Hutter; Jeffrey F Granger; Matthew D Beal; Robert A Siston
Journal:  Clin Orthop Relat Res       Date:  2013-02-08       Impact factor: 4.176

8.  Rotational references for total knee arthroplasty tibial components change with level of resection.

Authors:  Bradley P Graw; Alexander H Harris; Krishna R Tripuraneni; Nicholas J Giori
Journal:  Clin Orthop Relat Res       Date:  2010-03-30       Impact factor: 4.176

9.  Accuracy of anatomical references used for rotational alignment of tibial component in total knee arthroplasty.

Authors:  Namık Sahin; Teoman Atıcı; Alpaslan Öztürk; Güven Özkaya; Yüksel Özkan; Bülent Avcu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-15       Impact factor: 4.342

10.  The medial border of the tibial tuberosity as an auxiliary tool for tibial component rotational alignment during total knee arthroplasty (TKA).

Authors:  Michael Drexler; David Backstein; Ueli Studler; Dror Lakstein; Barak Haviv; Ran Schwarzkopf; Tal Frenkel Rutenberg; Yaniv Warschawski; Ehud Rath; Yona Kosashvili
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-03-26       Impact factor: 4.342

View more