Literature DB >> 11499626

Use of molecularly imprinted polymers in the solid-phase extraction of clenbuterol from animal feeds and biological matrices.

G Brambilla1, M Fiori, B Rizzo, V Crescenzi, G Masci.   

Abstract

Clenbuterol molecularly imprinted polymers (MIPs) as chromatographic stationary phase for the solid-phase extraction (SPE) of the drug from biological samples have been prepared. Propylene columns filled with 500 mg of clenbuterol MIPs have been tested with respect to their loading capacity, memory effects, selectivity toward related drugs (mabuterol, clenproperol, clenisopenterol, ritodrine) and specificity toward interferences arising from heterogeneous matrices such as animal feeds, bovine urine and liver. Analytes were concentrated on Extrelut 20 columns and the residues resuspended in 70% acetonitrile. Application, washing and elution fractions were collected and analyzed by HPLC-diode array detection. Results indicate this MIP approach in SPE is extremely selective for clenbuterol, mabuterol, clenproperol and clenisopenterol (>95% found in the eluate), with a loading capacity of about 20 microg/100 mg of stationary phase. Ritodrine showed a recovery rate of 51%. The molecular recognition mechanism is so specific to allow clenbuterol detection and identification by conventional detectors at level of interest (ppb) also from complex matrices such as feeds, urine and liver.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11499626     DOI: 10.1016/s0378-4347(01)00199-2

Source DB:  PubMed          Journal:  J Chromatogr B Biomed Sci Appl        ISSN: 1387-2273


  3 in total

1.  Selective Enrichment of Clenbuterol onto Molecularly Imprinted Polymer Microspheres with Tailor-made Structure and Oxygen Functionalities.

Authors:  Xiangyun Zhao; Yuliang Mai; Dongchu Chen; Min Zhang; Huawen Hu
Journal:  Polymers (Basel)       Date:  2019-10-10       Impact factor: 4.329

2.  Solid-phase extraction of exosomes from diverse matrices via a polyester capillary-channeled polymer (C-CP) fiber stationary phase in a spin-down tip format.

Authors:  Kaylan K Jackson; Rhonda R Powell; Terri F Bruce; R Kenneth Marcus
Journal:  Anal Bioanal Chem       Date:  2020-05-28       Impact factor: 4.478

3.  Rapid screening of toxic salbutamol, ractopamine, and clenbuterol in pork sample by high-performance liquid chromatography-UV method.

Authors:  Kunping Yan; Huiqun Zhang; Wenli Hui; Hongli Zhu; Xinbo Li; Fangyi Zhong; Xiu'e Tong; Chao Chen
Journal:  J Food Drug Anal       Date:  2016-02-23       Impact factor: 6.157

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.