Neck and whole-body scanning with 5-mCi dose of (123)I as diagnostic tracer in patients with well-differentiated thyroid cancer.

Z Gulzar1, S Jana, I Young, P Bukberg, V Yen, S Naddaf, H M Abdel-Dayem.   

Abstract

OBJECTIVE: To determine whether a 5-mCi dose of 123I can be used as an effective radiotracer for assessing the presence of remnant thyroid tissue and for searching for metastatic lesions in patients with well-differentiated thyroid cancer as well as to attempt to ascertain whether a scan performed only at 4 hours is sufficient for accurate diagnosis and might replace the conventional protocol of scanning at both 4 hours and 24 hours.
METHODS: We prospectively studied 27 patients who had undergone near-total thyroidectomy and had a documented diagnosis of well-differentiated thyroid carcinoma. Patients underwent scanning after receiving a 5-mCi dose of 123I, at a time when they had discontinued thyroid replacement therapy and had a thyrotropin level in excess of 30 mIU/mL. Whole-body images at 4 hours and 24 hours were obtained and were compared with posttherapy scans obtained 5 to 7 days after administration of 131I. Scans were interpreted by two board-certified nuclear medicine physicians.
RESULTS: Of the 27 patients, 2 (7.4%) showed discordance between the 123I scan performed at 24 hours and the posttherapy 131I scan. When 4-hour images after administration of 123I were compared with the posttherapy 131I scans, a discordance rate of 14.8% (4 of 27 patients) was noted. In addition, two of these four patients showed lesions on the 24-hour images that were not seen on the 4-hour images (one with new lung metastatic involvement and the other with a local recurrence in the lower neck area). The prognosis and treatment of these two patients were substantially changed by the result of the 24-hour images.
CONCLUSION: On comparison of scans obtained after administration of a 5-mCi dose of 123I with those obtained after 131I therapy, we conclude that 5 mCi of 123I produces images that have excellent quality and resolution and also compare favorably with those obtained after 131I therapy. Furthermore, a decrease in the dose of 123I from 10 mCi to 5 mCi lowered the cost of the study without compromising the diagnostic accuracy or image quality. Finally, use of 24-hour images will occasionally disclose additional areas of radioiodine uptake not detected on the 4-hour scans and is therefore recommended.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11497474

Source DB:  PubMed          Journal:  Endocr Pract        ISSN: 1530-891X            Impact factor:   3.443


  1 in total

1.  Should high hTg levels in the absence of iodine uptake be treated?

Authors:  K E Britton; R R Foley; S L Chew
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-03-04       Impact factor: 9.236

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.