Literature DB >> 11493282

Dose effect relationship of reviparin in chronic hemodialysis: a crossover study versus nadroparin.

I Reach1, N Luong, C Chastang, M Chakroun, S Mirshahi, M C Mirshahi, J Soria, D Desmichels, A Baumelou.   

Abstract

Low molecular weight heparins (LMWHs) are used for prevention of clotting in the dialysis circuit. The aim of this trial was to define the optimal dose of a new LMWH and to test the efficiency of a single dose at the start of the session. Fifteen patients were treated according to a double blind and crossover design during 4 blocks of 5 consecutive reviparin doses assigned randomly as 50, 60, 70, 85, and 100 IU anti-Xa/kg. Assessment was carried out on screening of fibrin rings or clots in the arterial and venous air traps and on visual detection of fiber in the dialyzer after rinsing. These clinical results were compared to plasmatic anti-Xa activity and thrombin-antithrombin (TAT) complex generation. A standard dose of 70 IU anti-Xa/kg of nadroparin was used as the control. After a bolus of 50 to 100 IU anti-Xa/kg, the occurrence of fibrin rings and clots in the air traps was dependent on three factors: dose of LMWH, time of the session, and patient status. A bolus of 85 IU anti-Xa/kg of reviparin was effective and safe for sessions of 4 h. For this dose, plasmatic anti-Xa activity was 0.96 +/- 0.28 IU/ml at Hour 2 and 0.82 +/- 0.22 IU/ml at Hour 4. TAT complexes are good markers of the activation of the coagulation. They did not increase during a 4 h session after a reviparin bolus of 100 IU/kg. For the same LMWH dose, the trial shows a great variability of the clinical effect and anti-Xa activities from one patient to another. A single dose of 85 IU anti-Xa/kg of reviparin can be used at the start of the dialysis session as a loading dose. We advise adapting the dose during the subsequent sessions according to the appearance of the blood circuit. The benefit of monitoring anti-Xa activity and TAT complexes could be tested in a further trial.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11493282     DOI: 10.1046/j.1525-1594.2001.025007591.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  1 in total

Review 1.  Efficacy and safety of low molecular weight heparin compared to unfractionated heparin for chronic outpatient hemodialysis in end stage renal disease: systematic review and meta-analysis.

Authors:  Ghanshyam Palamaner Subash Shantha; Anita Ashok Kumar; Mansha Sethi; Rohit C Khanna; Samir Bipin Pancholy
Journal:  PeerJ       Date:  2015-03-10       Impact factor: 2.984

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.