Literature DB >> 11491261

Intraoperative proximal endoleaks during AAA stent-graft repair: evaluation of risk factors and treatment with Palmaz stents.

N V Dias1, T Resch, M Malina, B Lindblad, K Ivancev.   

Abstract

PURPOSE: To study factors that might contribute to intraoperative proximal type I endoleak and to evaluate the placement of giant Palmaz stents as a therapeutic option.
METHODS: Thirty-three patients (30 men; median age 72 years, range 50-85) with abdominal aortic aneurysms underwent implantation of fully supported Gianturco Z-stent-based endografts (12 custom-made aortomonoiliac and 21 bifurcated Zenith devices). Ten (30%) patients were treated for intraoperative proximal endoleaks. Stent-graft oversizing and neck angulation, length, and shape were compared between patients with and without leaks.
RESULTS: In 9 cases, the endoleaks were successfully treated with intraoperative placement of Palmaz stents without complications. In 1 patient, a leak that was resolved intraoperatively with balloon dilation reappeared 1 month later; a Palmaz stent was deployed successfully. Stent-graft oversizing did not differ significantly between patients who developed proximal endoleaks and those who did not (median 4.0 mm in both groups, p = 0.47). Median neck length was 21.0 mm in patients with endoleak and 28.0 mm in those without (p > 0.99). Median neck angulation was 30 degrees in both groups (p = 0.33), and the presence of a conical aneurysm neck was not significantly different (2/10 versus 6/23, p > 0.99). All aneurysms remained excluded at a median follow-up of 13 months (range 6-24).
CONCLUSIONS: Stent-graft oversizing and neck morphology (length, angulation, and conical shape) do not seem to correlate with the incidence of proximal type I endoleaks. Palmaz stent placement appears to be a feasible and safe treatment option for this complication.

Entities:  

Mesh:

Year:  2001        PMID: 11491261     DOI: 10.1177/152660280100800306

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  2 in total

1.  Endovascular Aneurysm Repair in Patients with Conical Neck Anatomy.

Authors:  Jae Hoon Lee; Ki Hyuk Park
Journal:  Vasc Specialist Int       Date:  2017-06-30

2.  Severe infolding of fenestrated-branched endovascular stent graft.

Authors:  Aleem K Mirza; Giuliano A Sandri; Emanuel R Tenorio; Jussi M Kärkkäinen; Gustavo S Oderich
Journal:  J Vasc Surg Cases Innov Tech       Date:  2018-08-30
  2 in total