Predicting sulcus size using ocular measurements.

M Pop1, Y Payette, M Mansour.   

Abstract

PURPOSE: To predict sulcus size using ocular measurements.
SETTING: Michel Pop Clinics, Montreal, Quebec, Canada.
METHODS: Forty-three eyes were evaluated using several techniques. Ultrasound biomicroscopy (UBM) echograms were taken to measure the anterior chamber depth (ACD), sulcus size, and central corneal thickness. The limbus size was measured with a caliper. Axial length, ACD, and pachymetry were measured by contact ultrasonography. Refraction and corneal power were also evaluated.
RESULTS: The coefficient of linear regression was 0.05 between the limbus and the sulcus size (P =.78), 0.76 between ultrasonography and UBM ACD measurements (P <.001), and 0.69 between ultrasonography and UBM pachymetry (P <.001). Paired t tests showed that ultrasound and UBM ACD measurements were not statistically different (P =.70) but that ultrasound and UBM pachymetry measurements were (P <.001). The sulcus versus limbus difference was 0.6 mm for myopia and 0.3 mm for hyperopia. A backward elimination multiple regression performed with all measures to predict sulcus size resulted in the following formula: Sulcus size = 18.9 - 0.023 x sphere + 0.15 x mean keratometry (R = 0.49; P =.005; statistical power = 0.89; standard error of estimate = 0.5 mm).
CONCLUSION: Traditional estimation of sulcus size through limbal measurement is inadequate because limbus size alone cannot predict sulcus size. A general formula using the sphere and the mean corneal power can help predict sulcus size. Corneal power was significantly and negatively correlated with sulcus and limbus size as well as sphere. The standard error of sulcus measurement by UBM was 0.4 mm.

Entities:  

Mesh:

Year:  2001        PMID: 11489572     DOI: 10.1016/s0886-3350(00)00830-0

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  14 in total

1.  Accuracy, repeatability, and reproducibility of Artemis very high-frequency digital ultrasound arc-scan lateral dimension measurements.

Authors:  Dan Z Reinstein; Timothy J Archer; Ronald H Silverman; D Jackson Coleman
Journal:  J Cataract Refract Surg       Date:  2006-11       Impact factor: 3.351

2.  Outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of the Toric implantable collamer lens for high myopic astigmatism.

Authors:  Xun-Lun Sheng; Wei-Ning Rong; Qin Jia; Ya-Ni Liu; Wen-Juan Zhuang; Qing Gu; Yan Sun; Bo Pan; De-Jun Zhu
Journal:  Int J Ophthalmol       Date:  2012-08-18       Impact factor: 1.779

3.  Angle-to-angle and spur-to-spur distance analysis with high-resolution optical coherence tomography.

Authors:  Robert Montés-Micó; Pedro Tañá-Rivero; Salvador Aguilar-Córcoles; María Ruiz-Santos; María Dolores Rodríguez-Carrillo; Ramón Ruiz-Mesa
Journal:  Eye Vis (Lond)       Date:  2020-08-16

4.  Comparison of Eyemetrics and Orbscan automated method to determine horizontal corneal diameter.

Authors:  Arvind Venkataraman; Sapna K Mardi; Sarita Pillai
Journal:  Indian J Ophthalmol       Date:  2010 May-Jun       Impact factor: 1.848

5.  Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using artemis VHF digital ultrasound.

Authors:  Dan Z Reinstein; Timothy J Archer; Ronald H Silverman; Mark J Rondeau; D Jackson Coleman
Journal:  J Refract Surg       Date:  2009-02       Impact factor: 3.573

Review 6.  Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens.

Authors:  Mark Packer
Journal:  Clin Ophthalmol       Date:  2016-06-09

7.  Causes of Phakic Implantable Collamer Lens Explantation/Exchange at King Khaled Eye Specialist Hospital.

Authors:  Nasser A AlSabaani; Ashley Behrens; Sabah Jastanieah; Salem Al Malki; Mohanna Al Jindan; Saeed Al Motowa
Journal:  Middle East Afr J Ophthalmol       Date:  2016 Oct-Dec

8.  Buffering zone of implantable Collamer lens sizing in V4c.

Authors:  Seung Wan Nam; Dong Hui Lim; Joo Hyun; Eui-Sang Chung; Tae-Young Chung
Journal:  BMC Ophthalmol       Date:  2017-12-22       Impact factor: 2.209

9.  Adjustment formulae to improve the correlation of white-to-white measurement with direct measurement of the ciliary sulcus diameter by ultrasound biomicroscopy.

Authors:  Seyed Javad Hashemian; Majid Mohebbi; Mehdi Yaseri; Mohammad Ebrahim Jafari; Shadrokh Nabili; Seyed Mahyar Hashemian; Mahsa Sadat Hashemian
Journal:  J Curr Ophthalmol       Date:  2017-12-16

10.  Evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery.

Authors:  Ali Simsek; Süleyman Ciftci
Journal:  Clin Ophthalmol       Date:  2012-11-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.