Literature DB >> 11488864

Early endosseous integration enhanced by dual acid etching of titanium: a torque removal study in the rabbit.

P R Klokkevold1, P Johnson, S Dadgostari, A Caputo, J E Davies, R D Nishimura.   

Abstract

Textured implant surfaces are thought to enhance endosseous integration. Torque removal forces have been used as a biomechanical measure of anchorage, or endosseous integration, in which the greater forces required to remove implants may be interpreted as an increase in the strength of bony integration. The purpose of this study was to compare the torque resistance to removal of screw-shaped titanium implants having a dual acid-etched surface (Osseotite) with implants having either a machined surface, or a titanium plasma spray surface that exhibited a significantly more complex surface topography. Three custom screw-shaped implant types - machined, dual acid-etched (DAE), and titanium plasma sprayed (TPS) - were used in this study. Each implant surface was characterized by scanning electron microscopy and optical profilometry. One DAE implant was placed into each distal femur of eighteen adult New Zealand White rabbits along with one of the other implant types. Thus, each rabbit received two DAE implants and one each of the machined, or TPS, implants. All implants measured 3.25 mm in diameter x 4.00 mm in length without holes, grooves or slots to resist rotation. Eighteen rabbits were used for reverse torque measurements. Groups of six rabbits were sacrificed following one, two and three month healing periods. Implants were removed by reverse torque rotation with a digital torque-measuring device. Three implants with the machined surface preparation failed to achieve endosseous integration. All other implants were anchored by bone. Mean torque values for machined, DAE and TPS implants at one, two and three months were 6.00+/-0.64 N-cm, 9.07+/-0.67 N-cm and 6.73+/-0.95 N-cm; 21.86+/-1.37 N-cm, 27.63+/-3.41 N-cm and 27.40+/-3.89 N-cm; and 27.48+/-1.61 N-cm, 44.28+/-4.53 N-cm and 59.23+/-3.88 N-cm, respectively. Clearly, at the earliest time point the stability of DAE implants was comparable to that of TPS implants, while that of the machined implants was an order of magnitude lower. The TPS implants increased resistance to reverse torque removal over the three-month period. The results of this study confirm our previous results that demonstrated enhanced bony anchorage to dual acid-etched implants as compared to machined implants. Furthermore, the present results indicate that dual acid etching of titanium enhances early endosseous integration to a level which is comparable to that achieved by the topographically more complex TPS surfaces.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11488864     DOI: 10.1034/j.1600-0501.2001.012004350.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  31 in total

1.  Differentiation of human mesenchymal stem cells on niobium-doped fluorapatite glass-ceramics.

Authors:  Meenakshi Kushwaha; Xueliang Pan; Julie A Holloway; Isabelle L Denry
Journal:  Dent Mater       Date:  2011-11-09       Impact factor: 5.304

Review 2.  Surface treatments and roughness properties of Ti-based biomaterials.

Authors:  Andrea Bagno; Carlo Di Bello
Journal:  J Mater Sci Mater Med       Date:  2004-09       Impact factor: 3.896

3.  Simple coating with fibronectin fragment enhances stainless steel screw osseointegration in healthy and osteoporotic rats.

Authors:  Rachit Agarwal; Cristina González-García; Brennan Torstrick; Robert E Guldberg; Manuel Salmerón-Sánchez; Andrés J García
Journal:  Biomaterials       Date:  2015-06-15       Impact factor: 12.479

Review 4.  Animal models for periodontal regeneration and peri-implant responses.

Authors:  Alpdogan Kantarci; Hatice Hasturk; Thomas E Van Dyke
Journal:  Periodontol 2000       Date:  2015-06       Impact factor: 7.589

Review 5.  Biomaterial strategies for engineering implants for enhanced osseointegration and bone repair.

Authors:  Rachit Agarwal; Andrés J García
Journal:  Adv Drug Deliv Rev       Date:  2015-04-08       Impact factor: 15.470

6.  Peptide-functionalized poly[oligo(ethylene glycol) methacrylate] brushes on dopamine-coated stainless steel for controlled cell adhesion.

Authors:  Guillermo R Alas; Rachit Agarwal; David M Collard; Andrés J García
Journal:  Acta Biomater       Date:  2017-06-24       Impact factor: 8.947

7.  Histomorphometric evaluation of implants coated with enamel or dentine derived fluoride-substituted apatite.

Authors:  Mehmet Kürkcü; Mehmet Emre Benlidayi; Serhat Ozsoy; Lütfiye Sevgi Ozyeğin; Faik Nuzhet Oktar; Cem Kurtoğlu
Journal:  J Mater Sci Mater Med       Date:  2007-06-19       Impact factor: 3.896

8.  Effects of low-intensity pulsed ultrasound on dental implant osseointegration: a preliminary report.

Authors:  Yakup Ustun; Ozgur Erdogan; Mehmet Kurkcu; Tolga Akova; Ibrahim Damlar
Journal:  Eur J Dent       Date:  2008-10

9.  Nanocrystalline hydroxyapatite for bone repair: an animal study.

Authors:  J Brandt; S Henning; G Michler; W Hein; A Bernstein; M Schulz
Journal:  J Mater Sci Mater Med       Date:  2010-01       Impact factor: 3.896

10.  On the way to total integration of prosthetic pylon with residuum.

Authors:  Mark Pitkin
Journal:  J Rehabil Res Dev       Date:  2009
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.