Literature DB >> 11488568

Dosimetry of beta-ray ophthalmic applicators: comparison of different measurement methods.

C G Soares1, S Vynckier, H Järvinen, W G Cross, P Sipilä, D Flühs, B Schaeken, F A Mourtada, G A Bass, T T Williams.   

Abstract

An international intercomparison of the dosimetry of three beta particle emitting ophthalmic applicators was performed, which involved measurements with radiochromic film, thermoluminescence dosimeters (TLDs), alanine pellets, plastic scintillators, extrapolation ionization chambers, a small fixed-volume ionization chambers, a diode detector and a diamond detector. The sources studied were planar applicators of 90Sr-90Y and 106Ru-106Rh, and a concave applicator of 106Ru-106Rh. Comparisons were made of absolute dosimetry determined at 1 mm from the source surface in water or water-equivalent plastic, and relative dosimetry along and perpendicular to the source axes. The results of the intercomparison indicate that the various methods yield consistent absolute dosimetry results at the level of 10%-14% (one standard deviation) depending on the source. For relative dosimetry along the source axis at depths of 5 mm or less, the agreement was 3%-9% (one standard deviation) depending on the source and the depth. Crucial to the proper interpretation of the measurement results is an accurate knowledge of the detector geometry, i.e., sensitive volume and amount of insensitive covering material. From the results of these measurements, functions which describe the relative dose rate along and perpendicular to the source axes are suggested.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11488568     DOI: 10.1118/1.1376441

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Monte Carlo Computation of Dose-Volume Histograms in Structures at Risk of an Eye Irradiated with Heterogeneous Ruthenium-106 Plaques.

Authors:  Francisco J Zaragoza; Marion Eichmann; Dirk Flühs; Beate Timmermann; Lorenzo Brualla
Journal:  Ocul Oncol Pathol       Date:  2020-07-20

2.  Monte Carlo simulation of tilted contact plaque brachytherapy placement for juxtapapillary retinoblastoma.

Authors:  Satoshi Nakamura; Naoya Murakami; Shigenobu Suzuki; Kimiteru Ito; Mihiro Takemori; Hiroki Nakayama; Keita Kaga; Takahito Chiba; Kotaro Iijima; Kana Takahashi; Tomonori Goka; Jun Itami; Hiroyuki Okamoto; Hiroshi Igaki
Journal:  Radiat Oncol       Date:  2022-01-24       Impact factor: 3.481

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.