Literature DB >> 11487679

Use of ethylene vinyl alcohol copolymer for tubal sterilization by selective catheterization in rabbits.

N Abdala1, A Levitin, A Dawson, R Maffra, H Munoz-Ramirez, K Godec, B L Dolmatch.   

Abstract

PURPOSE: To assess the efficacy of ethylene vinyl alcohol copolymer (Uryx) in nonsurgically occluding the fallopian tube and achieving tubal sterilization in the rabbit model.
MATERIALS AND METHODS: Ten mature virgin female New England rabbits underwent transvaginal selective bilateral fallopian tube cannulation with use of a coaxial catheter system under general anesthesia. Selective salpingography was performed bilaterally to assess patency of the fallopian tubes. Ethylene vinyl alcohol copolymer was injected unilaterally through a microcatheter to completely fill the middle portion of the tube. Three to seven days after injection, each animal was bred. Conception was determined by ultrasonography (US) 7-19 days after effective breeding. If pregnant, the rabbit was killed. Otherwise, it was permitted to rebreed until pregnancy was achieved. Histologic specimens of the fallopian tubes were prepared and analyzed.
RESULTS: Patency of the fallopian tubes was demonstrated bilaterally in all animals by the free spillage of contrast material into the peritoneum. The delivery of ethylene vinyl alcohol copolymer into the fallopian tubes was successful in all animals but one, in which most of the plug almost immediately extruded into the uterus. Pregnancy was detected by US in the untreated fallopian tube in the nine rabbits that were receptive to breeding. No pregnancies were detected in the injected side. Histologic analysis demonstrated variable degrees of occlusion, fibrosis, and inflammation, with the majority of specimens demonstrating mild to moderate inflammation and moderate to marked fibrosis.
CONCLUSION: Ethylene vinyl alcohol copolymer can reliably be placed nonsurgically via the transvaginal approach into the fallopian tubes with use of a coaxial catheter system. Ethylene vinyl alcohol copolymer appears to result in less fibrosis than previously investigated agents and demonstrates a 100% early sterilization rate in the rabbit model.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11487679     DOI: 10.1016/s1051-0443(07)61579-6

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  4 in total

1.  Basics and Principles in the Application of Onyx LD Liquid Embolic System in the Endovascular Treatment of Cerebral Arteriovenous Malformations.

Authors:  R Siekmann
Journal:  Interv Neuroradiol       Date:  2005-10-27       Impact factor: 1.610

2.  Long-term results and patients' satisfaction after transurethral ethylene vinyl alcohol (Tegress) injections: a two-centre study.

Authors:  Annette Kuhn; Werner Stadlmayr; Amara Sohail; Ash Monga
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2007-10-23

3.  Uretero-fallopian fistula after hysteroscopy fallopian tube embolization: a case report.

Authors:  Yumeng Zhang; Tianjia Ma; Guangfeng Shao; Zhiying Xiao
Journal:  BMC Urol       Date:  2018-08-22       Impact factor: 2.264

Review 4.  Recent progress in advanced biomaterials for long-acting reversible contraception.

Authors:  Mingzhe Yan; Yanming Zhang; Zhihang Wu; Yifei Li; Keke Dou; Banghui Wang; Yingruo Wang; Qihui Zhou
Journal:  J Nanobiotechnology       Date:  2022-03-17       Impact factor: 10.435

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.