Literature DB >> 11486824

Enantiomeric separation of metoprolol and alpha-hydroxymetoprolol by liquid chromatography and fluorescence detection using a chiral stationary phase.

B Mistry1, J L Leslie, N D Eddington.   

Abstract

A sensitive and stereoselective high-performance liquid chromatographic assay for the determination of the enantiomers of metoprolol (R- and S-) and the diastereoisomers of alpha-hydroxymetoprolol (IIA, IIB) in plasma is reported. Chromatography involved direct separation of enantiomers using a Chirobiotic T bonded phase column (250 x 4.6 mm) and a mobile phase consisting of acetonitrile-methanol-methylene chloride-glacial acetic acid-triethylamine (56:30:14:2:2, v/v). Solid-phase extraction using silica bonded with ethyl group (C2) was used to extract the compounds of interest from plasma and atenolol was used as the internal standard. The column effluent was monitored using fluorescence detection with excitation and emission wavelengths of 225 and 310 nm, respectively. S-Metoprolol, R-metoprolol, IIB and IIA eluted at about 5.9, 6.7, 7.3 and 8.2 min without any interfering peaks. The calibration curve was linear over the range of 0.5 to 100 ng/ml for each isomer of metoprolol and 1 to 100 ng/ml for each isomer of alpha-hydroxymetoprolol (IIA & IIB). The mean intra-run accuracies were in the range of 96.2 to 114% for R-metoprolol, 94.0 to 111% for S-metoprolol, 90.2 to 110% for IIA, and 94.6 to 106% for IIB. The mean intra-run precisions were all in the range of 2.2 to 12.0% for R-metoprolol, 2.1 to 11.1% for S-metoprolol, 1.9 to 14.5% for IIA, and 3.2 to 11.0% for IIB. The lowest level of quantitation for the enantiomers of metoprolol was 0.5 ng/ml and 1.0 ng/ml for alpha-hydroxymetoprolol (IIA and IIB). The absolute recoveries for each analyte was > or = 95%. The validated method accurately quantitated the enantiomers of parent drug and metabolite after a single dose of an extended release metoprolol formulation.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11486824     DOI: 10.1016/s0378-4347(01)00166-9

Source DB:  PubMed          Journal:  J Chromatogr B Biomed Sci Appl        ISSN: 1387-2273


  3 in total

1.  Development of a sensitive and rapid method for quantitation of (S)-(-)- and (R)-(+)-metoprolol in human plasma by chiral LC-ESI-MS/MS.

Authors:  Primal Sharma; Pritesh Contractor; Swati Guttikar; Daxesh P Patel; Pranav S Shrivastav
Journal:  J Pharm Anal       Date:  2013-03-05

2.  Rapid and sensitive LC-MS/MS method for the determination of metoprolol in Beagle dog plasma with a simple protein precipitation treatment and its pharmacokinetic applications.

Authors:  Sha Li; Xingli Wang; Kelong Peng; Zhiguo Ma; Xiaoqi Zhang; Shaolian Fu; Xiaofei Li; Linlin Li; Aihua Hong; Jie Jiang
Journal:  Molecules       Date:  2012-03-05       Impact factor: 4.411

3.  Chiral separation of beta-blockers by high-performance liquid chromatography and determination of bisoprolol enantiomers in surface waters.

Authors:  Marijana Pocrnić; Martin Ansorge; Magda Dovhunová; Iva Habinovec; Eva Tesařová; Nives Galić
Journal:  Arh Hig Rada Toksikol       Date:  2020-03-01       Impact factor: 1.948

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.