Literature DB >> 11484579

Resistance to staining, flexural strength, and chemical solubility of core porcelains for all-ceramic crowns.

J F Esquivel-Upshaw1, J Chai, S Sansano, D Shonberg.   

Abstract

PURPOSE: The increased demand for tooth-colored restorations has prompted the use of ceramics in areas that are subject to masticatory stresses. To maximize the strength of these restorations, manufacturers and clinicians advocate placement of core materials in lieu of veneering materials in areas that are more susceptible to fracture. The objectives of this study were to determine the: resistance to staining of three core porcelains used for all-ceramic restorations, Procera, IPS Empress, and In-Ceram, through the use of colorimetry and visual observation; flexural strength of these porcelains under a three-point bend test; and chemical solubility in a controlled environment.
MATERIALS AND METHODS: L*a*b* values were obtained for each specimen before and after immersion in a saturated solution of methylene blue in ethanol for 24 hours. Visual observation was also performed to ascertain color differences before and after staining. A three-point bend test was used to determine flexural strength. A reflux-condenser type, three-piece extraction apparatus was used with 4% acetic acid solution for 16 hours to determine solubility. Each sample was weighed before and after the reflux procedure to ascertain percentage weight loss.
RESULTS: The mean delta E obtained for IPS Empress was 14.5; In-Ceram was 9.2, and Procera was 9.0. Flexural strength obtained for IPS Empress, In-Ceram, and Procera was 176.9 MPa, 323.4 MPa, and 464.3 MPa, respectively. Weight loss of IPS Empress, In-Ceram, and Procera was 0.056%, 0.734%, and 0.003%, respectively.
CONCLUSION: IPS Empress showed the least resistance to staining. IPS Empress had the lowest flexural strength, while Procera had the highest. In-Ceram demonstrated the highest chemical solubility.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11484579

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  3 in total

1.  Analysis of Translucency Parameter of Glass-Ceramics Fabricated by Different Techniques.

Authors:  Karla Ledić; Igor Majnarić; Slađana Milardović; Stipe Špalj; Sanja Štefančić; Ketij Mehulić
Journal:  Acta Stomatol Croat       Date:  2015-03

2.  Novel Testing for Corrosion of Glass-Ceramics for Dental Applications.

Authors:  J F Esquivel-Upshaw; F Ren; S M Hsu; F Y Dieng; D Neal; A E Clark
Journal:  J Dent Res       Date:  2017-09-18       Impact factor: 6.116

3.  Surface degradation of glass ceramics after exposure to acidulated phosphate fluoride.

Authors:  Vanessa Zulema S Ccahuana; Mutlu Ozcan; Alfredo Mikail Melo Mesquita; Renato Sussumo Nishioka; Estevão Tomomitsu Kimpara; Marco Antonio Bottino
Journal:  J Appl Oral Sci       Date:  2010 Mar-Apr       Impact factor: 2.698

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.