Literature DB >> 11481835

Evaluation of an internal thoracic artery as a coronary artery bypass graft by intercostal duplex scanning ultrasonography.

N Ohtani1, K Kiyokawa, H Asada, T Kawakami, M Haga, N Akasaka.   

Abstract

OBJECTIVES: Although angiography is often used to determine whether the internal thoracic artery is appropriate as a coronary bypass graft, but use of duplex scanning ultrasonography for this purpose is not yet widespread.
METHODS: The internal diameter and flow of the internal thoracic artery were measured using intercostal duplex scanning in 100 patients during April 1995. The ultrasonographic device (sonos 2000, Hewlett Packard) used had a linear probe delivering a frequency of 7.5 MHz. Bilateral internal thoracic arteries and their blood flow were imaged clearly in all subjects. Diameter was compared by angiography and duplex scanning ultrasonography in 20 patients.
RESULTS: The average internal diameter of internal thoracic artery was 2.19 +/- 0.46 mm (right) or 2.13 +/- 0.32 mm (left) in men and 2.05 +/- 0.44 mm (right) or 2.09 +/- 0.42 mm (left) in women. The gender difference was statistically significant (p = 0.05). The maximum systolic blood flow velocity through the internal thoracic artery was 0.85 +/- 0.34 m/s (right) or 0.84 +/- 0.36 m/s (left) in men and 0.87 +/- 0.28 m/s (right) or 0.82 +/- 0.28 m/s (left) in women. The average internal thoracic arterial blood flow (F) was 54.6 +/- 29.0 ml/min (right) or 50.9 +/- 28.8 ml/min (left) in men and 56.8 +/- 38.2 ml/min (right) or 58.2 +/- 33.4 ml/min (left) in women. Duplex scanning ultrasonography using an intercostal approach enables easy imaging of bilateral internal thoracic arteries and visualizes entire internal thoracic artery structure by simply changing the probe position.
CONCLUSION: Intercostal duplex scanning ultrasonography is thus recommended for reliable evaluation of the internal diameter and blood flow of the internal thoracic artery.

Entities:  

Mesh:

Year:  2001        PMID: 11481835     DOI: 10.1007/bf02913147

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  11 in total

1.  Long-term benefits of internal thoracic artery-coronary artery bypass in Japanese patients.

Authors:  S Kitamura; K Kawachi; S Taniguchi; T Kawata; S Kobayashi; H Nishioka; K Mizuguchi; K Niwaya; Y Kameda; H Sakaguchi
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  1998-01

2.  [Noninvasive hemodynamic assessment of internal thoracic artery grafts using duplex echocardiography from supraclavicular fossa--a comparison with Doppler catheter method].

Authors:  Y Furutani; T Takahashi; H Imagawa; K Taniguchi; K Kadoba; H Matsuda; J Arisawa; M Higashi
Journal:  Nihon Kyobu Geka Gakkai Zasshi       Date:  1997-11

3.  The assessment of internal mammary artery grafts by colour Doppler in coronary artery surgery.

Authors:  M Süngün; E Duran; B S Cebeci; M H Us; D Saba; G Saygin
Journal:  J Cardiovasc Surg (Torino)       Date:  1998-02       Impact factor: 1.888

4.  [A histologic study of atherosclerosis of the internal mammary artery used for coronary artery bypass surgery].

Authors:  H Kobayashi; S Kitamura; C Oyama; K Kawachi; Y Koh; R Morita; T Nishii; S Taniguchi; T Seki; K Inoue
Journal:  Nihon Kyobu Geka Gakkai Zasshi       Date:  1987-09

5.  Coronary arterial bypass grafts.

Authors:  G E Green; S H Stertzer; E H Reppert
Journal:  Ann Thorac Surg       Date:  1968-05       Impact factor: 4.330

6.  [Quantitative hemodynamic assessment of internal thoracic artery grafts using transthoracic duplex imaging].

Authors:  H Takemura; M Kawasuji; N Sakakibara; Y Matsumoto; S Fujii; T Ushijima; Y Watanabe
Journal:  Nihon Kyobu Geka Gakkai Zasshi       Date:  1994-12

7.  [Description of arterial grafts from the aspect of preoperative angiography].

Authors:  Y Kawaue; S Hayashi
Journal:  Nihon Kyobu Geka Gakkai Zasshi       Date:  1994-01

8.  Duplex sonography of the internal thoracic artery. Preoperative assessment.

Authors:  H J Sons; R Marx; E Godehardt; B Lösse; J Kunert; W Bircks
Journal:  J Thorac Cardiovasc Surg       Date:  1994-09       Impact factor: 5.209

9.  Internal mammary artery: a "live" conduit for coronary bypass.

Authors:  R N Singh; J A Sosa
Journal:  J Thorac Cardiovasc Surg       Date:  1984-06       Impact factor: 5.209

10.  [Noninvasive assessment of left internal thoracic artery graft patency using transthoracic echocardiography].

Authors:  Y Goto; H Atsumi; K Kadowaki; T Sato; Y Abe; A Nakakomi; T Kumagai; T Abe
Journal:  Nihon Kyobu Geka Gakkai Zasshi       Date:  1993-10
View more
  1 in total

1.  Importance of duplex scanning ultrasonography evaluation of the proximal internal thoracic artery as a coronary artery bypass graft.

Authors:  Yuichiro Kaminishi
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2002-12
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.