Literature DB >> 11481509

Percutaneous suture closure for management of large French size arterial puncture in aortic valvuloplasty.

L W Solomon, B Fusman, N Jolly, A Kim, T Feldman.   

Abstract

Percutaneous aortic valvuloplasty produces acute hemodynamic and clinical improvement in patients with aortic stenosis who are poor candidates for surgical valve replacement. The benefits of this procedure are mitigated by the high restenosis rates and 1--2 year mortality, in addition to significant vascular complications associated with the large arterial puncture necessary for retrograde arterial approaches. We describe the use of suture closure techniques to reduce the vascular morbidity associated with this procedure. We reviewed 31 consecutive patients who underwent percutaneous aortic valvuloplasty and suture closure with the Perclose device between April 1998 and September 2000. After diagnostic catheterization using 6--8 French (Fr) sheaths, an 8 or 10 Fr Perclose device was preloaded into the artery and the untied sutures left in place. A 12.5 or 14 Fr sheath was passed over the wire, through the sutures. The sutures were tied at the conclusion of the procedure, in conjunction with sheath removal. Twenty-seven out of 31 patients (87%) had successful suture closure of the arteriotomy and did not require prolonged bed rest, manual compression or a compression device. There were 4 failures of percutaneous suture closure, requiring conventional manual compression and bed rest for hemostasis. No patient required surgical repair of the arteriotomy, nor were there any limb complications. Compared to 39 consecutive prior patients who had their arterial puncture managed with manual compression, length of stay was shorter (2.2 days versus 5.3 days) and fewer patients received blood transfusions (0% versus 29%). Preloaded suture closure of the arterial puncture is a useful technique for achieving hemostasis after removal of the large sheaths used for percutaneous valvuloplasty, and reduces the post-procedure patient discomfort and prolonged bed rest associated with this procedure.

Entities:  

Mesh:

Year:  2001        PMID: 11481509

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  6 in total

Review 1.  Amyloid fibrils from the viewpoint of protein folding.

Authors:  S Ohnishi; K Takano
Journal:  Cell Mol Life Sci       Date:  2004-03       Impact factor: 9.261

2.  Revival of an old method with new techniques: balloon aortic valvuloplasty of the calcified aortic stenosis in the elderly.

Authors:  Stefan Sack; Philipp Kahlert; Sasan Khandanpour; Christoph Naber; Sebastian Philipp; Stefan Möhlenkamp; Burkhard Sievers; Hagen Kälsch; Raimund Erbel
Journal:  Clin Res Cardiol       Date:  2008-04-03       Impact factor: 5.460

Review 3.  [Decompensated valve failure: the revival of balloon valvuloplasty - percutaneous valve intervention].

Authors:  Stefan Sack; Jochen Menne; Thomas Krüger; Michael Weber; Dieter Müller; Werner Zwehl
Journal:  Herz       Date:  2009-05       Impact factor: 1.443

Review 4.  Technique of transcatheter aortic valve implantation with the Edwards-Sapien heart valve using the transfemoral approach.

Authors:  Alain Cribier; Pierre-Yves Litzler; Helene Eltchaninoff; Matthieu Godin; Christophe Tron; Fabrice Bauer; Jean-Paul Bessou
Journal:  Herz       Date:  2009-08       Impact factor: 1.443

Review 5.  The complexity of parathyroid hormone-related protein signalling.

Authors:  E Maioli; V Fortino
Journal:  Cell Mol Life Sci       Date:  2004-02       Impact factor: 9.261

6.  Transradial unprotected left main coronary stenting supported by percutaneous Impella Recover LP 2.5 assist device.

Authors:  H H Minden; H Lehmann; J Meyhöfer; C Butter
Journal:  Clin Res Cardiol       Date:  2006-03-21       Impact factor: 6.138

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.