Literature DB >> 11477249

Mr flow measurement in the internal mammary artery-to-coronary artery bypass graft: comparison with graft stenosis at radiographic angiography.

N Ishida1, H Sakuma, B P Cruz, T Shimono, T Tokui, I Yada, K Takeda, C B Higgins.   

Abstract

PURPOSE: To evaluate the sensitivity and specificity of breath-hold magnetic resonance (MR) flow measurement for detection of significant stenosis in internal mammary artery bypass grafts.
MATERIALS AND METHODS: Twenty-six consecutive patients who had undergone coronary artery bypass surgery were examined. Breath-hold velocity-encoded cine MR images were obtained at the midpoint of the internal mammary artery between its origin from the subclavian artery and the distal anastomosis to the left anterior descending artery.
RESULTS: MR images were obtained successfully in 24 patients. At conventional angiography, no significant stenosis was observed in 17 patients (group A), and significant stenosis (diameter > 70%) was observed in seven patients (group B). The mean diastolic-to-systolic peak velocity ratio in group B (0.61 +/- 0.44 [SD]) was significantly lower than that in group A (1.88 +/- 0.96; P <.01). Evaluation of graft stenosis with the diastolic-to-systolic peak velocity ratio revealed a sensitivity of 86% and a specificity of 88%. The mean blood flow rate at baseline in group B (16.9 mL/min +/- 5.5) was significantly lower than that in group A (79.8 mL/min +/- 38.2; P <.01). The sensitivity and specificity of MR blood flow measurement in predicting significant stenosis were 86% and 94%, respectively. The mean pharmacologic flow reserve ratios were 2.00 +/- 1.43 in group A and 1.39 +/- 1.46 in group B (P >.05).
CONCLUSION: Fast MR blood flow measurement at baseline is highly useful for predicting significant stenosis in internal mammary arterial grafts.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11477249     DOI: 10.1148/radiology.220.2.r01au16441

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

Review 1.  Cardiovascular nuclear magnetic resonance: basic and clinical applications.

Authors:  John R Forder; Gerald M Pohost
Journal:  J Clin Invest       Date:  2003-06       Impact factor: 14.808

2.  Magnetic resonance imaging for the non-invasive detection of stenosis in coronary artery bypass grafts: clinical reality?

Authors:  E E van der Wall; S E Langerak
Journal:  Int J Cardiovasc Imaging       Date:  2002-12       Impact factor: 2.357

3.  MR-based coronary artery blood velocity measurements in patients without coronary artery disease.

Authors:  M Schiemann; F Bakhtiary; V Hietschold; A Koch; A Esmaeili; H Ackermann; A Moritz; T J Vogl; N D Abolmaali
Journal:  Eur Radiol       Date:  2006-01-13       Impact factor: 5.315

4.  MRI in the detection of stenosis in coronary artery bypass grafts: are invasive techniques still needed?

Authors:  S E Langerak; E E van der Wall
Journal:  Neth Heart J       Date:  2003-01       Impact factor: 2.380

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.