Optimisation and evaluation of an electromagnetic tracking device for high-accuracy three-dimensional ultrasound imaging of the carotid arteries.

D C Barratt1, A H Davies, A D Hughes, S A Thom, K N Humphries.   

Abstract

Electromagnetic tracking devices provide a flexible, low cost solution for three-dimensional ultrasound (3-D US) imaging. They are, however, susceptible to interference. A commercial device (Ascension pcBIRD) was evaluated to assess the accuracy in locating the scan probe as part of a digital, freehand 3-D US imaging system aimed at vascular applications. The device was optimised by selecting a measurement rate and filter setting that minimised the mean deviation in repeated position and orientation measurements. Experimental evaluation of accuracy indicated that, overall, absolute errors were small: the RMS absolute error was 0.2 mm (range: -0.7 to 0.5 mm) for positional measurements over translations up to 90 mm, and 0.2 degrees (range: -0.8 to 0.9 degrees ) for rotational measurements up to 30 degrees. In the case of position measurements, the absolute errors were influenced by the location of the scanner relative to the scan volume. We conclude that the device tested provides an accuracy sufficient for use within a freehand 3-D US system for carotid artery imaging.

Mesh:

Year:  2001        PMID: 11476930     DOI: 10.1016/s0301-5629(01)00395-7

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Reconstruction and positional accuracy of 3D ultrasound on vertebral phantoms for adolescent idiopathic scoliosis spinal surgery.

Authors:  Andrew Chan; Eric Parent; Edmond Lou
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-12-05       Impact factor: 2.924

2.  Automatic virtual transducer locating system to assist in interpreting ultrasound imaging.

Authors:  Nobuyuki Taniguchi; Tomoyuki Kuwata; Tomoko Ono; Kouichi Itoh; Kiyoka Omoto; Yasutomo Fujii; Akifumi Ootake
Journal:  J Med Ultrason (2001)       Date:  2003-12       Impact factor: 1.314

3.  A personalized image-guided intervention system for peripheral lung cancer on patient-specific respiratory motion model.

Authors:  Tengfei Wang; Tiancheng He; Zhenglin Zhang; Qi Chen; Liwei Zhang; Guoren Xia; Lizhuang Yang; Hongzhi Wang; Stephen T C Wong; Hai Li
Journal:  Int J Comput Assist Radiol Surg       Date:  2022-05-31       Impact factor: 3.421

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.