Literature DB >> 11476682

Effect of cataract extraction on blue-on-yellow visual field.

Y Y Kim1, J S Kim, D H Shin, C Kim, H R Jung.   

Abstract

PURPOSE: It is assumed that cataract can influence the results of blue-on-yellow perimetry. However, actual sensitivity change in blue-on-yellow perimetry before and after cataract surgery has not been fully demonstrated.
METHODS: Prospective.
SETTING: Institutional. STUDY POPULATION: Twenty-two eyes of 22 consecutive patients without ocular pathology, other than cataract, known to influence visual field undergoing cataract surgery. OBSERVATION PROCEDURES: Both white-on-white (W-W) and blue-on-yellow (B-Y) perimetries. MAIN OUTCOME MEASURES: Global indexes including mean deviation and other pertinent data of white-on-white and blue-on-yellow perimetries were compared before and after cataract surgery.
RESULTS: Mean deviation was improved after cataract surgery in both white-on-white perimetry (from -6.88 dB to -3.36 dB, P <.0001) and blue-on-yellow perimetry (from -12.22 dB to -3.64 dB, P <.0001, paired t test). However, the mean difference between preoperative and postoperative mean deviation in blue-on-yellow perimetry (8.58 +/- 3.96 dB) was significantly higher than that of white-on-white perimetry (3.52 +/- 2.69 dB; P <.0001, unpaired t test). That is, the change in mean deviation was greater in blue-on-yellow perimetry than in white-on-white perimetry by a factor of 2.4 times.
CONCLUSION: Cataract causes predominantly a general reduction of sensitivity in both blue-on-yellow and white-on-white perimetries, and the general reduction of blue-on-yellow sensitivity is far greater than that of white-on-white sensitivity.

Entities:  

Mesh:

Year:  2001        PMID: 11476682     DOI: 10.1016/s0002-9394(01)00969-2

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  8 in total

Review 1.  Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma.

Authors:  M A R Siddiqui; A Azuara-Blanco; S Neville
Journal:  Br J Ophthalmol       Date:  2005-12       Impact factor: 4.638

Review 2.  [Frequency-doubling technology : A new method for determining glaucomatous visual field defects].

Authors:  J Lamparter; A Schulze; E M Hoffmann
Journal:  Ophthalmologe       Date:  2009-08       Impact factor: 1.059

Review 3.  Does Posterior Capsule Opacification Affect the Results of Diagnostic Technologies to Evaluate the Retina and the Optic Disc?

Authors:  Jose Javier Garcia-Medina; Monica Del Rio-Vellosillo; Vicente Zanon-Moreno; Enrique Santos-Bueso; Roberto Gallego-Pinazo; Antonio Ferreras; Maria Dolores Pinazo-Duran
Journal:  Biomed Res Int       Date:  2015-06-08       Impact factor: 3.411

4.  Utility of blue-on-yellow perimetry in the evaluation of patients with idiopathic optic neuropathy.

Authors:  Shinji Makino
Journal:  Clin Ophthalmol       Date:  2013-06-27

5.  Cerebral trauma-induced dyschromatopsia in the left hemifield: case presentation.

Authors:  Yoko Mase; Yoshitsugu Matsui; Eriko Uchiyama; Hisashi Matsubara; Masahiko Sugimoto; Akiko Kubo; Mineo Kondo
Journal:  BMC Ophthalmol       Date:  2021-01-27       Impact factor: 2.209

6.  Comparison of SWAP and SAP on the point of glaucoma conversion.

Authors:  Ioannis Havvas; Dimitris Papaconstantinou; Marilita M Moschos; Panagiotis G Theodossiadis; Vasilios Andreanos; Pantelis Ekatomatis; Ioannis Vergados; Dimitrios Andreanos
Journal:  Clin Ophthalmol       Date:  2013-09-19

7.  Effect of yellow-tinted intraocular lens on standard automated perimetry and short wavelength automated perimetry in patients with glaucoma.

Authors:  Naveed Nilforushan; Mohammad Parsamanesh; Fei Yu; Nariman Nassiri; Arezoo Miraftabi; Anne L Coleman
Journal:  Middle East Afr J Ophthalmol       Date:  2014 Jul-Sep

8.  Changes in Visual Field Indices after Pterygium Surgery.

Authors:  Fikret Ucar; Halil Ibrahim Yener; Servet Cetinkaya; Huseyina Ture
Journal:  Beyoglu Eye J       Date:  2021-12-17
  8 in total