Literature DB >> 11475948

Efficacy of laser Doppler flowmetry for the diagnosis of revascularization of reimplanted immature dog teeth.

K Yanpiset1, N Vongsavan, A Sigurdsson, M Trope.   

Abstract

UNLABELLED: This study was performed to assess if laser Doppler flowmetry (LDF) is an improved method for the detection of revascularization of replanted teeth. Teeth were extracted and reimplanted under different experimental conditions. LDF readings were taken before extraction and weekly for 3 months. In control teeth, LDF baseline readings were taken and then repeated after the apical blood vessels were cut surgically. At the end of 3 months it was determined radiographically and histologically whether revascularization had occurred, i.e. vitality had returned.
RESULTS: LDF readings correctly predicted the pulp status (vital vs. non-vital) in 83.7% of the readings. 73.9% (17 of 23) were correct for the vital teeth and 95% (19 of 20) were correct for the non-vital teeth. Fisher's exact test (2-tail) indicated that there was no significant association between the efficacy of LDF and tooth type (P = 0.166), although P2 was the least accurate tooth tested. Wilcoxon's matched-pair signed rank test demonstrated that in the revascularized (vital) teeth, the flux value between the baseline and week 2 dropped significantly (P = 0.0001), increased significantly from week 2 to week 4 (P = 0.0001) and then decreased steadily until week 12. However, at week 12 the flux was still significantly higher than at week 2 (P = 0.010). In the teeth that failed to revascularize, the flux value dropped significantly by weeks 1 and 2 (P = 0.004 and P = 0.0001, respectively). Flux values did not increase from week 2. A Fast Fourier Transform (FFT) analysis confirmed a pulse of dominant frequency of 2 Hz in the teeth that returned to vitality and the lack thereof in those that stayed non-vital. One tooth in which the flux value evaluation indicated a non-vital tooth but the radiographic/histologic findings showed vital (false negative) possessed a pulse of dominant frequency and proved by this method to have successfully revascularized.

Entities:  

Mesh:

Year:  2001        PMID: 11475948     DOI: 10.1034/j.1600-9657.2001.017002063.x

Source DB:  PubMed          Journal:  Dent Traumatol        ISSN: 1600-4469            Impact factor:   3.333


  7 in total

1.  Pulpal blood flow changes in abutment teeth of removable partial dentures.

Authors:  Göknil Ergün Kunt; Deniz Kökçü; Gözlem Ceylan; Nergiz Yilmaz; Ahmet Umut Güler
Journal:  Bosn J Basic Med Sci       Date:  2009-11       Impact factor: 3.363

2.  Effect of extracorporeal shockwave therapy (ESWT) on pulpal blood flow after orthodontic treatment: a randomized clinical trial.

Authors:  Frank Falkensammer; Wolfgang Schaden; Christoph Krall; Josef Freudenthaler; Hans-Peter Bantleon
Journal:  Clin Oral Investig       Date:  2015-07-17       Impact factor: 3.573

3.  Pulp sensibility tests responses in patients with anxiety and depression.

Authors:  Narges Farhad-Mollashahi; Mahboubeh-Firouzkouhi Moghadam; Seyed-Mohammad-Javad Aslani; Forugh Mollashahi
Journal:  J Clin Exp Dent       Date:  2022-05-01

4.  Efficiency of new custom-made pulse oximeter sensor holder in assessment of actual pulp status.

Authors:  Krishnamachari Janani; P Ajitha; Raghu Sandhya; Haripriya Subbaiyan; Jerry Jose
Journal:  J Family Med Prim Care       Date:  2020-07-30

5.  Evaluation of efficacy of a pulse oximeter to assess pulp vitality.

Authors:  Mohammed Sadique; S V Ravi; Kunjamma Thomas; Prasanth Dhanapal; Elsy P Simon; Mohammed Shaheen
Journal:  J Int Oral Health       Date:  2014-06-26

Review 6.  Applications of sensory and physiological measurement in oral-facial dental pain.

Authors:  Darya Dabiri; Daniel E Harper; Yvonne Kapila; Grant H Kruger; Daniel J Clauw; Steven Harte
Journal:  Spec Care Dentist       Date:  2018-09-08

7.  Doppler flowmetry as a tool of predictive, preventive and personalised dentistry.

Authors:  Liudmila Yu Orekhova; Anna A Barmasheva
Journal:  EPMA J       Date:  2013-08-28       Impact factor: 6.543

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.