Knowledge-based segmentation of pediatric kidneys in CT for measurement of parenchymal volume.

M S Brown1, W C Feng, T R Hall, M F McNitt-Gray, B M Churchill.   

Abstract

PURPOSE: The purpose of this work was to develop an automated method for segmenting pediatric kidneys in helical CT images and measuring their volume.
METHOD: An automated system was developed to segment the kidneys. Parametric features of anatomic structures were used to guide segmentation and labeling of image regions. Kidney volumes were calculated by summing included voxels. For validation, the kidney volumes of four swine were calculated using our approach and compared with the "true" volumes measured after harvesting the kidneys. Automated volume calculations were also performed in a cohort of nine children.
RESULTS: The mean difference between the calculated and measured values in the swine kidneys was 1.38 ml. For the pediatric cases, calculated volumes ranged from 41.7 to 252.1 ml/kidney, and the mean ratio of right to left kidney volume was 0.96.
CONCLUSION: These results demonstrate the accuracy of a volumetric technique that may in the future provide an objective assessment of renal damage.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11473198     DOI: 10.1097/00004728-200107000-00021

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  3 in total

1.  The effect of lung volume on nodule size on CT.

Authors:  Iva Petkovska; Matthew S Brown; Jonathan G Goldin; Hyun J Kim; Michael F McNitt-Gray; Fereidoun G Abtin; Raffi J Ghurabi; Denise R Aberle
Journal:  Acad Radiol       Date:  2007-04       Impact factor: 3.173

2.  Are renal volumes measured by magnetic resonance imaging and three-dimensional ultrasound in the term neonate comparable?

Authors:  Alison L Kent; Rajeev Jyoti; Cameron Robertson; Lisa Gonsalves; Sandra Meskell; Bruce Shadbolt; Michael C Falk
Journal:  Pediatr Nephrol       Date:  2010-05       Impact factor: 3.714

3.  Effect of various environments and computed tomography scanning parameters on renal volume measurements in vitro: A phantom study.

Authors:  Wangyan Liu; Yinsu Zhu; Lijun Tang; Xiaomei Zhu; Yi Xu; Guanyu Yang
Journal:  Exp Ther Med       Date:  2016-06-01       Impact factor: 2.447

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.