Literature DB >> 11473179

High b-value diffusion-weighted MRI of normal brain.

J H Burdette1, D D Durden, A D Elster, Y F Yen.   

Abstract

PURPOSE: As MR scanner hardware has improved, allowing for increased gradient strengths, we are able to generate higher b values for diffusion-weighted (DW) imaging. Our purpose was to evaluate the appearance of the normal brain on DW MR images as the diffusion gradient strength ("b value") is increased from 1,000 to 3,000 s/mm2.
METHOD: Three sets of echo planar images were acquired at 1.5 T in 25 normal subjects (mean age 61 years) using progressively increasing strengths of a diffusion-sensitizing gradient (corresponding to b values of 0, 1,000, and 3,000 s/mm2). All other imaging parameters remained constant. Qualitative assessments of trace images were performed by two neuroradiologists, supplemented by quantitative measures of MR signal and noise in eight different anatomic regions.
RESULTS: As gradient strength increased from b = 1,000 to 3,000, both gray and white matter structures diminished in signal as expected based on their relative diffusion coefficients [calculated average apparent diffusion coefficient (ADC) values: gray matter = 8.5 x 10(-4) mm2/s, white matter = 7.5 x 10(-4) mm2/s]. The signal-to-noise ratios for the b = 1,000 images were approximately 2.2 times higher than for the b = 3,000 images (p < 0.0001). As the strength of the diffusion-sensitizing gradient increased, white matter became progressively hyperintense to gray matter. Relative to the thalamus, for example, the average MR signal intensity of white matter structures increased by an average of 27.5%, with the densely packed white matter tracts (e.g., middle cerebellar peduncle, tegmentum, and internal capsule) increasing the most.
CONCLUSION: Brain DW images obtained at b = 3,000 appear significantly different from those obtained at b = 1,000, reflecting expected loss of signal from all areas of brain in proportion to their ADC values. Consequently, when all other imaging parameters are held constant, b = 3,000 DW images appear significantly noisier than b = 1,000 images, and white matter tracts are significantly more hyperintense than gray matter structures.

Entities:  

Mesh:

Year:  2001        PMID: 11473179     DOI: 10.1097/00004728-200107000-00002

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  22 in total

Review 1.  Methodology of diffusion-weighted, diffusion tensor and magnetisation transfer imaging.

Authors:  S J Price; D J Tozer; J H Gillard
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  Early detection of global cerebral anoxia: improved accuracy by high-b-value diffusion-weighted imaging with long echo time.

Authors:  Khin K Tha; Satoshi Terae; Toru Yamamoto; Kohsuke Kudo; Chihiro Takahashi; Masaki Oka; Shinji Uegaki; Kazuo Miyasaka
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

3.  High b-value diffusion (b = 3000 s/mm2) MR imaging in cerebral gliomas at 3T: visual and quantitative comparisons with b = 1000 s/mm2.

Authors:  H S Seo; K-H Chang; D G Na; B J Kwon; D H Lee
Journal:  AJNR Am J Neuroradiol       Date:  2007-12-07       Impact factor: 3.825

4.  Quantitative diffusion tensor MR imaging of the brain: field strength related variance of apparent diffusion coefficient (ADC) and fractional anisotropy (FA) scalars.

Authors:  Thierry A G M Huisman; Thomas Loenneker; Gerd Barta; Matthias E Bellemann; Juergen Hennig; Joachim E Fischer; Kamil A Il'yasov
Journal:  Eur Radiol       Date:  2006-03-11       Impact factor: 5.315

5.  Apparent diffusion coefficient with higher b-value correlates better with viable cell count quantified from the cavity of brain abscess.

Authors:  V Tomar; A Yadav; R K S Rathore; S Verma; R Awasthi; V Bharadwaj; B K Ojha; K N Prasad; R K Gupta
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-08       Impact factor: 3.825

Review 6.  A decade of DTI in traumatic brain injury: 10 years and 100 articles later.

Authors:  M B Hulkower; D B Poliak; S B Rosenbaum; M E Zimmerman; M L Lipton
Journal:  AJNR Am J Neuroradiol       Date:  2013-01-10       Impact factor: 3.825

Review 7.  Radiological assessment of Creutzfeldt-Jakob disease.

Authors:  Henriette J Tschampa; Inga Zerr; Horst Urbach
Journal:  Eur Radiol       Date:  2006-11-09       Impact factor: 5.315

8.  The value of multi ultra high-b-value DWI in grading cerebral astrocytomas and its association with aquaporin-4.

Authors:  Yan Tan; Hui Zhang; Xiao-Chun Wang; Jiang-Bo Qin; Le Wang
Journal:  Br J Radiol       Date:  2018-03-20       Impact factor: 3.039

9.  The basics of diffusion and perfusion imaging in brain tumors.

Authors:  Panagiotis Korfiatis; Bradley Erickson
Journal:  Appl Radiol       Date:  2014-07-04

10.  Repeatability, reproducibility, and accuracy of quantitative mri of the breast in the community radiology setting.

Authors:  Anna G Sorace; Chengyue Wu; Stephanie L Barnes; Angela M Jarrett; Sarah Avery; Debra Patt; Boone Goodgame; Jeffery J Luci; Hakmook Kang; Richard G Abramson; Thomas E Yankeelov; John Virostko
Journal:  J Magn Reson Imaging       Date:  2018-03-23       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.