OBJECTIVE: To evaluate the role of transesophageal echocardiography (TEE) in detecting cardiac and thoracic aortic sources of retinal emboli. DESIGN: Retrospective observational case series. PARTICIPANTS: The study population consisted of 18 patients who were initially seen with retinal artery occlusion (7 central, 11 branch) and underwent TEE as part of the systemic evaluation. INTERVENTION: All patients underwent TEE, consisting of complete two-dimensional and Doppler color flow examinations. TEE was done immediately after transthoracic echo (TTE) examination. The medical records were reviewed. MAIN OUTCOME MEASURE: Detection of a possible cardiac or thoracic aortic source of retinal embolus. RESULTS: Cardiac or thoracic aortic pathologic conditions, which were a possible source of the retinal emboli, were detected by TEE in 13 of the 18 patients (72%). They included aortic arch atheroma (n = 7), mitral annulus calcification (n = 4), left atrial appendage thrombus (n = 2), valvular abnormalities (n = 5), left atrial smoke (n = 3), and patent foramen ovale (n = 3). In 11 patients (61%), at least one cardiac or aortic source of emboli detected by TEE was missed by TTE. Significant carotid artery disease (>or=40% stenosis) was present in 3 of 16 patients (17%). CONCLUSIONS: TEE is a potentially useful modality for detecting possible sources of retinal artery emboli and may be considered as an adjunct to the routine evaluation of affected patients.
OBJECTIVE: To evaluate the role of transesophageal echocardiography (TEE) in detecting cardiac and thoracic aortic sources of retinal emboli. DESIGN: Retrospective observational case series. PARTICIPANTS: The study population consisted of 18 patients who were initially seen with retinal artery occlusion (7 central, 11 branch) and underwent TEE as part of the systemic evaluation. INTERVENTION: All patients underwent TEE, consisting of complete two-dimensional and Doppler color flow examinations. TEE was done immediately after transthoracic echo (TTE) examination. The medical records were reviewed. MAIN OUTCOME MEASURE: Detection of a possible cardiac or thoracic aortic source of retinal embolus. RESULTS: Cardiac or thoracic aortic pathologic conditions, which were a possible source of the retinal emboli, were detected by TEE in 13 of the 18 patients (72%). They included aortic arch atheroma (n = 7), mitral annulus calcification (n = 4), left atrial appendage thrombus (n = 2), valvular abnormalities (n = 5), left atrial smoke (n = 3), and patent foramen ovale (n = 3). In 11 patients (61%), at least one cardiac or aortic source of emboli detected by TEE was missed by TTE. Significant carotid artery disease (>or=40% stenosis) was present in 3 of 16 patients (17%). CONCLUSIONS: TEE is a potentially useful modality for detecting possible sources of retinal artery emboli and may be considered as an adjunct to the routine evaluation of affected patients.
Authors: Christine Benn Christiansen; Christian Torp-Pedersen; Jonas Bjerring Olesen; Gunnar Gislason; Morten Lamberts; Nicholas Carlson; Mathias Buron; Nikolai Juul; Gregory Y H Lip Journal: BMC Cardiovasc Disord Date: 2018-05-10 Impact factor: 2.298