Literature DB >> 11470691

INTACS inserts for treating keratoconus: one-year results.

J Colin1, B Cochener, G Savary, F Malet, D Holmes-Higgin.   

Abstract

OBJECTIVE: To evaluate the use of INTACS micro-thin prescription inserts (Kera Vision, Inc., Fremont, CA) for the treatment of keratoconus.
DESIGN: Prospective, nonrandomized (self-controlled) comparative trial. PARTICIPANTS/INTERVENTION: Ten patients from our prospective clinical study who had completed 12 months of follow-up were evaluated. All patients had keratoconus with clear central corneas and were contact lens intolerant. After reviewing corneal pachymetry and topography of individual patients, INTACS inserts of 0.45-mm thickness were placed in the inferior cornea to lift the cone and INTACS of 0.25-mm thickness were inserted superiorly to counterbalance and flatten the overall anterior corneal surface. MAIN OUTCOME MEASURES: Differences between preoperative and postoperative uncorrected visual acuity, best spectacle-corrected visual acuity, manifest refraction, and keratometry values were statistically assessed. Changes in corneal ectasia were evaluated by reviewing corneotopographic maps.
RESULTS: No intraoperative complications occurred in this series of patients. Spherical equivalent error and refractive astigmatism were reduced with INTACS inserts treatment. Postoperative month 12 uncorrected visual acuity (logarithm of the minimum angle of resolution [logMAR] mean, 0.35, standard deviation [SD], 0.16 [approximately 20/50, approximately 2 lines]) was significantly better than preoperative (logMAR mean, 1.05; SD, 0.33 [approximately 20/200, approximately 3 lines]; P <or=0.05). Average best spectacle-corrected visual acuity at postoperative month 12 was improved by approximately two lines compared with baseline (logMAR mean, 0.22; SD, 0.12 [approximately 20/32, approximately 1 line]; logMAR mean, 0.38; SD, 0.13 [approximately 20/50, approximately 1 line], respectively). Topographic corneal shape (size and height of the cone) was improved for all subjects after insert placement.
CONCLUSIONS: INTACS micro-thin prescription inserts seem to provide a viable method for treating clear corneal keratoconus for patients who are contact lens intolerant. The corneal steepening and astigmatism associated with keratoconus were reduced, and visual acuity was improved with treatment in almost all eyes.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11470691     DOI: 10.1016/s0161-6420(01)00646-7

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  39 in total

1.  [Femtosecond laser in refractive surgery].

Authors:  H B Dick
Journal:  Ophthalmologe       Date:  2006-12       Impact factor: 1.059

Review 2.  INTACS for keratoconus.

Authors:  Yaron S Rabinowitz
Journal:  Int Ophthalmol Clin       Date:  2006

3.  Optical coherence tomography to assess intrastromal corneal ring segment depth in keratoconic eyes.

Authors:  Michael M Lai; Maolong Tang; Eduardo M M Andrade; Yan Li; Rahul N Khurana; Jonathan C Song; David Huang
Journal:  J Cataract Refract Surg       Date:  2006-11       Impact factor: 3.351

4.  [Ex- und reimplantation of intracorneal ring segments with the support of femtosecond laser, Femtec, for the treatment of progressive keratoconus].

Authors:  M Tomalla
Journal:  Ophthalmologe       Date:  2007-04       Impact factor: 1.059

5.  Implantable collamer lenses after intracorneal ring segments for keratoconus.

Authors:  Alejandro Navas; Guillermo Tapia-Herrera; Martha Jaimes; Enrique O Graue-Hernández; Arturo Gomez-Bastar; Tito Ramirez-Luquín; Arturo Ramirez-Miranda
Journal:  Int Ophthalmol       Date:  2012-05-12       Impact factor: 2.031

6.  Preliminary results of a new intrastromal corneal ring segment as a tissue saving procedure in photorefractive keratectomy to correct moderate to high myopia.

Authors:  Sandro Coscarelli; Pablo Rodrigues; Guilherme Rocha; Leonardo Torquetti
Journal:  Int J Ophthalmol       Date:  2020-12-18       Impact factor: 1.779

7.  Treatment of moderate to severe keratoconus with 6-mm Intacs SK.

Authors:  Sasan Niknam; Mehrdad Shamshiri; Seyed Sahabaldin Shahrzad; Abbas Alipour; Mohammad Bagher Rajabi; Mohammad Taher Rajabi
Journal:  Int J Ophthalmol       Date:  2012-08-18       Impact factor: 1.779

8.  New surgical approaches to the management of keratoconus and post-LASIK ectasia.

Authors:  Bryan U Tan; Tracy L Purcell; Luis F Torres; David J Schanzlin
Journal:  Trans Am Ophthalmol Soc       Date:  2006

Review 9.  INTACS for keratoconus and ectasia after LASIK.

Authors:  Yaron S Rabinowitz
Journal:  Int Ophthalmol Clin       Date:  2013

10.  Intrastromal corneal ring implants for corneal thinning disorders: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2009-04-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.