Literature DB >> 11469296

A comparative scanning electron microscopic investigation of the efficacy of manual and automated instrumentation of root canals.

E Schäfer1, K Zapke.   

Abstract

The cleaning effectiveness of automated and manual root canal instrumentation was investigated with the aid of a scanning electron microscope. Hand instrumentation was performed with K-Flexofiles used in a reaming working motion and according to the step-back technique and with Hedstrom files used in a filing motion. Automated preparation was performed with the KaVo-Endo Flash device featuring torque-limited rotation using K-Flexofiles, as well as with the mechanical ProFile system using rotary nickel-titanium instruments. Twelve teeth each with either straight or curved root canals were instrumented to size 40. After cracking the roots longitudinally (n = 120), the amount of debris and smear layer were quantified on the basis of a numerical evaluation scale (1 through 5). Comparison of manual instrumentation with the automated KaVo-Endo Flash resulted in an equivalent degree of canal cleaning. Complete cleanliness was not achieved by any of the techniques and devices investigated. Best instrumentation results, especially in curved canals, were obtained with rotary ProFile instruments.

Mesh:

Substances:

Year:  2000        PMID: 11469296     DOI: 10.1097/00004770-200011000-00007

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  15 in total

1.  Smear Layer Evaluation on Root Canal Preparation with Manual and Rotary Techniques using EDTA as an Irrigant: A Scanning Electron Microscopy Study.

Authors:  M Manjunatha; Kini Annapurna; V Sudhakar; Vc Sunil Kumar; Vinay Kumar Hiremath; Ankur Shah
Journal:  J Int Oral Health       Date:  2013-02-26

2.  Comparative evaluation of instrumentation timing and cleaning efficacy in extracted primary molars using manual and NiTi rotary technique - Invitro study.

Authors:  Rachita Mehlawat; Rishabh Kapoor; Kapil Gandhi; Dipanshu Kumar; Ritika Malhotra; Shilpa Ahuja
Journal:  J Oral Biol Craniofac Res       Date:  2019-03-17

3.  Comparison of the cleaning capacity of Mtwo and Pro Taper rotary systems and manual instruments in primary teeth.

Authors:  Mohammad Reza Azar; Laya Safi; Afshin Nikaein
Journal:  Dent Res J (Isfahan)       Date:  2012-03

4.  A scanning electron microscope study on the effect of an experimental irrigation solution on smear layer removal.

Authors:  Vahid Zand; Hadi Mokhtari; Mehrdad Lotfi; Saeed Rahimi; Aydin Sohrabi; Sina Badamchi Zadeh; Hanieh Mojaver Kahnamooie; Pardis Tehranchi
Journal:  Iran Endod J       Date:  2014-03-08

5.  A comparative scanning electron microscope investigation of cleanliness of root canals using hand k-flexofiles, rotary race and k3 instruments.

Authors:  Saeed Rahimi; Vahid Zand; Sharhriar Shahi; Sahar Shakouie; Mohammad Forough Reyhani; Mohammad Mohammadi Khoshro; Pardis Tehranchi
Journal:  Iran Endod J       Date:  2008-10-01

6.  SEM Study of Root Canal Walls Cleanliness after Ni-Ti Rotary and Hand Instrumentation.

Authors:  Noosha Khadivi Nia Javan; Ladan Mohajeri Baradaran; Shahram Azimi
Journal:  Iran Endod J       Date:  2007-04-01

7.  Effect of master apical file size and taper on irrigation and cleaning of the apical third of curved canals.

Authors:  Nahid Mohammadzadeh Akhlaghi; Bahareh Dadresanfar; Soheila Darmiani; Amirabbas Moshari
Journal:  J Dent (Tehran)       Date:  2014-03-31

8.  A comparative evaluation of different irrigation activation systems on smear layer removal from root canal: An in-vitro scanning electron microscope study.

Authors:  Nishi Singh; Anil Chandra; Aseem P Tikku; Promila Verma
Journal:  J Conserv Dent       Date:  2014-03

9.  Comparison of the cleaning efficacy of the FKG race system and hand instrument in molar root canal.

Authors:  Carla Renata Sipert; Renata Pardini Hussne; Celso Kenji Nishiyama
Journal:  J Appl Oral Sci       Date:  2006-01       Impact factor: 2.698

10.  Smear Layer Removal in the Apical Third of Root Canals by Two Chelating Agents and Laser: A Comparative in vitro Study.

Authors:  Hengameh Ashraf; Mohammad Asnaashari; Soheila Darmiani; Reza Birang
Journal:  Iran Endod J       Date:  2014-07-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.