Literature DB >> 11467530

An acetylcholinesterase/choline oxidase-based amperometric biosensors as a liquid chromatography detector for acetylcholine and choline determination in brain tissue homogenates.

A Guerrieri1, F Palmisano.   

Abstract

A liquid chromatography (LC) detector based on a fast response and sensitive bienzyme amperometric biosensor for acetylcholine (ACh) and choline (Ch) is described. The detector fabrication consisted of glutaraldehyde co-crosslinking of acetylcholinesterase and choline oxidase with bovine serum albumin on the Pt working electrode of a conventional thin-layer electrochemical flow cell. The influence of some experimental parameters (e.g., enzyme loading, thickness of the bienzyme layer, flow rate) on the detector characteristics has been studied in order to optimize the analyte response while minimizing band-broadening and distortion. A mobile phase consisting of a phosphate buffer (I, 0.1 M; pH, 6.5) containing 5 mM sodium hexane sulfonate and 10 mM tetramethylammonium phosphate was found to give very satisfactory resolution and peak shape in ion-pair, reversed-phase LC. Linear responses were observed over at least four decades and absolute detection limits (at a signal-to-noise ratio of 3) were 12 and 27 fmol injected for Ch and ACh, respectively. After one month of intensive use in the LC system, the detector retained about 70% of its initial sensitivity. The potential of the described approach is demonstrated by the simultaneous determination of Ch and ACh in rat brain tissue homogenates.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11467530     DOI: 10.1021/ac000852h

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  Nanotechnology-based electrochemical sensors for biomonitoring chemical exposures.

Authors:  Richard C Barry; Yuehe Lin; Jun Wang; Guodong Liu; Charles A Timchalk
Journal:  J Expo Sci Environ Epidemiol       Date:  2008-11-19       Impact factor: 5.563

2.  Critical Evaluation of Acetylcholine Determination in Rat Brain Microdialysates using Ion-Pair Liquid Chromatography with Amperometric Detection.

Authors:  Dimitri De Bundel; Sophie Sarre; Ann Van Eeckhaut; Ilse Smolders; Yvette Michotte
Journal:  Sensors (Basel)       Date:  2008-08-28       Impact factor: 3.576

3.  A Crosstalk- and Interferent-Free Dual Electrode Amperometric Biosensor for the Simultaneous Determination of Choline and Phosphocholine.

Authors:  Rosanna Ciriello; Antonio Guerrieri
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.576

Review 4.  Recent Advances in In Vivo Neurochemical Monitoring.

Authors:  Chao Tan; Elaine M Robbins; Bingchen Wu; Xinyan Tracy Cui
Journal:  Micromachines (Basel)       Date:  2021-02-18       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.