Literature DB >> 11467435

Quantitative evaluation of hypothermia, hyperthermia, and hemodilution on coagulation.

S A Kmiecik1, J L Liu, T S Vaadia, J D Nichols, R J Kohtz, N J Mills, C M Petterson, A H Stammers.   

Abstract

The purpose of this study was to investigate the effects of temperature change on the coagulation time of blood at two different hematocrit levels by using various coagulation-monitoring devices. The devices used in this study were the Bayer Rapid Point Coag Analyzers, Hemochron Jr. Signature, Hemochron Response, Medtronic ACT II, and Haemoscope Thrombelastograph. One unit of human bank blood was used in this study. The hematocrit level was adjusted to 40% and 20%. A control bath and experimental bath were set up. Control blood was maintained at 37 degrees C and tested every 45 +/- 15 min throughout the experimental period of 6 h to demonstrate the stability of the model. The experimental blood was tested at temperature points of 37, 32, 27, 32, 37, 42, and 37 degrees C. Activated clotting time (ACT) tended to increase when the temperature was initially decreased from 37 to 27 degrees C, which reached a statistically significant level when measured by the Hemochron Response at both the 20% (147 +/- 10.7 to 159.3 +/- 11.0, p < .0332) and 40% hematocrit level (130 +/- 14.9 to 152.1 +/- 19.7, p < .0148). ACT was decreased significantly (p < .05) when the temperature was increased to 42 degrees C as measured by all machines except the Hemochron Jr. Signature at the 20% hematocrit level. ACT was significantly higher (p < .05) at a 20% hematocrit level as compared to that at a 40% hematocrit level on all devices for the majority of temperature points. These data suggested that hypothermia only increased ACT when measured by a macrosample device requiring a milliliter sample (Hemochron Response). However, hemodilution induced anticoagulatory effects and hyperthermia caused an acceleration in coagulation by all devices utilized in this study.

Entities:  

Mesh:

Year:  2001        PMID: 11467435

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  4 in total

Review 1.  The hemostatic defect of cardiopulmonary bypass.

Authors:  Matthew Dean Linden
Journal:  J Thromb Thrombolysis       Date:  2003-12       Impact factor: 2.300

2.  The influence of sampling technique on ACT Plus results.

Authors:  Monique E Brouwer; Ramen Miraziz; Grace Agbulos; Rona Steel; Peter Hales; Peter Klineberg
Journal:  J Extra Corpor Technol       Date:  2012-12

Review 3.  Coagulopathy in traumatic brain injury.

Authors:  Sherman C Stein; Douglas H Smith
Journal:  Neurocrit Care       Date:  2004       Impact factor: 3.210

4.  Long-term extracorporeal circulation management: the role of low- and high-range heparin ACT tests.

Authors:  Daniel Herbst; Hani K Najm; Kumar Neerod Jha
Journal:  J Extra Corpor Technol       Date:  2008-12
  4 in total