Literature DB >> 11466651

Mechanics of the antebrachial interosseous membrane: response to shearing forces.

J C McGinley1, L D'addessi, K Sadeghipour, S H Kozin.   

Abstract

The interosseous membrane functions to maintain the structural integrity of the forearm; however, the age-related mechanical properties of the intact membrane are incompletely defined. The purpose of this study is to quantify the mechanical properties of the interosseous membrane by applying a quasi-equilibrium shearing force between the radius and ulna. A 5-cm section of the central (main and accessory bundles) fiber from 11 (5 male and 6 female) fresh-frozen cadaver arms (age, 74 +/- 6.9 years) was isolated with the radial and ulnar attachments, measured, and positioned into the testing apparatus. A shear force was applied at 12.7 mm/min to produce a quasi-equilibrium state, and the applied force and elongation were monitored. The average ultimate force, ultimate strength, and elastic modulus were 1101 +/- 191 N, 13.98 +/- 4.85 MPa, and 135.29 +/- 41.57 MPa, respectively. Age-related changes were also noted with an increase in thickness by 0.056 mm per year of age and a decrease in fiber stiffness of 4.78 MPa/yr. The age-related mechanical properties of the intact interosseous membrane are necessary for modeling forearm stability in normal and pathologic conditions. This information is required for analysis of repair or reconstructive procedures.

Mesh:

Year:  2001        PMID: 11466651     DOI: 10.1053/jhsu.2001.24961

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  7 in total

1.  Forearm interosseous membrane trauma: MRI diagnostic criteria and injury patterns.

Authors:  Joseph C McGinley; Neil Roach; Brendon C Hopgood; Karl Limmer; Scott H Kozin
Journal:  Skeletal Radiol       Date:  2006-02-22       Impact factor: 2.199

2.  Ligamentoplasty of the forearm interosseous membrane using the semitendinosus tendon: anatomical study and surgical procedure.

Authors:  M Soubeyrand; C Oberlin; C Dumontier; Z Belkheyar; C Lafont; R Degeorges
Journal:  Surg Radiol Anat       Date:  2006-02-11       Impact factor: 1.246

Review 3.  The role of ultrasound and magnetic resonance imaging in the evaluation of the forearm interosseous membrane. A review.

Authors:  Juan Rodriguez-Martin; Juan Pretell-Mazzini
Journal:  Skeletal Radiol       Date:  2011-05-20       Impact factor: 2.199

4.  Form and function of the oblique cord (chorda obliqua) in anthropoid primates.

Authors:  Biren A Patel
Journal:  Primates       Date:  2004-07-07       Impact factor: 2.163

5.  MRI detection of forearm soft tissue injuries with radial head fractures.

Authors:  Joseph C McGinley; Garry Gold; Emilie Cheung; Jeffrey Yao
Journal:  Hand (N Y)       Date:  2014-03

6.  Forearm Interosseous Membrane Maintains the Stability of Proximal Radioulnar Joint.

Authors:  Ning Zhang; Jia-Hu Fang
Journal:  Orthop Surg       Date:  2020-12-21       Impact factor: 2.071

7.  Digitalization of the IOM: A comprehensive cadaveric study for obtaining three-dimensional models and morphological properties of the forearm's interosseous membrane.

Authors:  Fabio Carrillo; Simon Suter; Fabio A Casari; Reto Sutter; Ladislav Nagy; Jess G Snedeker; Philipp Fürnstahl
Journal:  Sci Rep       Date:  2020-04-14       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.