The neurologic and adaptive capacity score is not a reliable method of newborn evaluation.

S H Halpern1, J A Littleford, N J Brockhurst, P J Youngs, N Malik, H C Owen.   

Abstract

BACKGROUND: The Neurologic and Adaptive Capacity Score (NACS) is a multi-item scale that was published in 1982 to measure the effects of intrapartum drugs on the neonate. Although this scoring system has been widely used in obstetric anesthesia research, studies confirming its reliability have not been published. The purpose of this study was to assess the reliability of the NACS.
METHODS: Two teams of observers were trained to perform the NACS on healthy, term neonates born in the vertex presentation. Two examinations were performed on each neonate within the first 2.5 h of life. Simultaneous (or "split-half") reliability was assessed using the alpha coefficient. Test-retest reliability was assessed using the intraclass correlation coefficient. The test was considered to be reliable if a was greater than 0.7 and the intraclass correlation coefficient was greater than 0.6.
RESULTS: Two hundred babies were studied. The a was 0.47 and the intraclass correlation coefficient was 0.38 (95% confidence interval, 0.24-0.52).
CONCLUSIONS: The NACS had poor reliability both on simultaneous testing and in the test-retest situation when used to evaluate term, healthy neonates. The authors suggest that other measures need to be developed to evaluate the effect of intrapartum drug administration in the neonate. Health measurement scales should undergo rigorous assessment for reliability and validity before they are used in clinical practice or for research purposes.

Entities:  

Mesh:

Year:  2001        PMID: 11465620     DOI: 10.1097/00000542-200106000-00007

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  2 in total

1.  A randomized study of the effects of perioperative i.v. lidocaine on hemodynamic and hormonal responses for cesarean section.

Authors:  Mohamed R El-Tahan; Osama M Warda; Douaa G Diab; Eyad A Ramzy; Mohamed K Matter
Journal:  J Anesth       Date:  2009-05-15       Impact factor: 2.078

2.  Comparison of bupivacaine and ropivacaine in combination with fentanyl used for walking epidural anesthesia in labor.

Authors:  Şükrü Gündüz; Serenat Eriş Yalçın; Gökhan Karakoç; Mehmet Özgür Akkurt; Yakup Yalçın; And Yavuz
Journal:  Turk J Obstet Gynecol       Date:  2017-09-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.