Literature DB >> 11465298

Audiometric evaluation of bilaterally fitted bone-anchored hearing aids.

A J Bosman1, A F Snik, C T van der Pouw, E A Mylanus, C W Cremers.   

Abstract

Bilateral fittings of bone-anchored hearing aids (BAHA) were evaluated in 25 patients with at least 3 months experience with using two BAHAs. For all patients, air conduction hearing aids were contraindicated due to either recurrent otorrhoea or otitis externa (19 cases) or to congenital aural atresia (six cases). Candidacy for bilateral fitting was primarily based on symmetry of bone conduction thresholds. For all patients, measurements comprised sound localisation, speech recognition in quiet and in noise. In addition, in a subgroup of nine patients, release from masking for pure-tone stimuli in noise with interaural phase differences (binaural masking level difference. BMLD) was measured. The percentage of correct localisation judgments with 500-Hz and 2-kHz noise bursts increased significantly (p<0.01) from 22.2 per cent and 24.3 per cent for unilateral fittings to 41.8 per cent and 45.3 per cent for bilateral fittings, respectively. With unilateral fittings sound localisation judgments appeared to be strongly biased to the ipsilateral BAHA side. whereas with bilateral fittings, judgments were far more symmetrical. The speech reception threshold for sentences in quiet was significantly (p<0.01) better for the bilateral fittings compared to the unilateral fittings: 37.5 dBA versus 41.7 dBA. Speech recognition in noise was measured with the speech signal presented in front of the listener and a 65-dBA masking noise at either +90 degrees or -90 degrees azimuth. For noise presented at the ipsilateral side of the first fitted BAHA, the signal-to-noise ratio was significantly reduced (p<0.01) from -0.7 dB for the unilateral fitting to -4.0 dB for the bilateral fitting. The speech reception threshold in noise was not significantly different (p>0.05) for unilateral and bilateral fittings when the noise was presented at the contralateral side of the first fitted BAHA. The results for the six patients with congenital atresia are comparable with those for the other patients. So, directional hearing and speech recognition in noise improve significantly with a second BAHA. The BMLD measurements showed a significant (p<0.01) release from masking of 6.1, 6.0 and 6.6 dB for 125-Hz, 250-Hz and 500-Hz stimuli, respectively. The BMLD effect of 4.1 dB at 1,000 Hz was not significant at the 5 per cent level. The positive results with the bilateral fittings in quiet can be ascribed to increased stimulus levels due to diotic summation of signals from either side. The results for localisation, speech recognition in noise and BMLD measurements indicate that bilaterally fitted BAHAs do indeed (to some extent) result in binaural hearing.

Entities:  

Mesh:

Year:  2001        PMID: 11465298

Source DB:  PubMed          Journal:  Audiology        ISSN: 0020-6091


  16 in total

1.  Results and complications of the Baha system (bone-anchored hearing aid).

Authors:  G Ricci; A Della Volpe; M Faralli; F Longari; M Gullà; N Mansi; A Frenguelli
Journal:  Eur Arch Otorhinolaryngol       Date:  2010-06-10       Impact factor: 2.503

2.  Simulation study of power and sample size for repeated measures with multinomial outcomes: an application to sound direction identification experiments (SDIE).

Authors:  Dingfeng Jiang; Jacob J Oleson
Journal:  Stat Med       Date:  2011-07-12       Impact factor: 2.373

3.  Intracochlear Measurements of Interaural Time and Level Differences Conveyed by Bilateral Bone Conduction Systems.

Authors:  Nyssa F Farrell; Renee M Banakis Hartl; Victor Benichoux; Andrew D Brown; Stephen P Cass; Daniel J Tollin
Journal:  Otol Neurotol       Date:  2017-12       Impact factor: 2.311

4.  BAHA: Bone-Anchored Hearing Aid.

Authors:  Abdulrahman Hagr
Journal:  Int J Health Sci (Qassim)       Date:  2007-07

5.  BAHA®: The Direct Bone Conductor.

Authors:  Patrik Westerkull
Journal:  Trends Amplif       Date:  2002-06

6.  [Integration of the active middle ear implant Vibrant Soundbridge in total auricular reconstruction].

Authors:  B Wollenberg; M Beltrame; R Schönweiler; E Gehrking; S Nitsch; A Steffen; H Frenzel
Journal:  HNO       Date:  2007-05       Impact factor: 1.284

7.  Bone anchored hearing aid: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2002-09-01

Review 8.  [Bone anchored hearing aids (BAHA)].

Authors:  P A Federspil
Journal:  HNO       Date:  2009-03       Impact factor: 1.284

9.  Pilot study on the effectiveness of the conventional CROS, the transcranial CROS and the BAHA transcranial CROS in adults with unilateral inner ear deafness.

Authors:  Myrthe K S Hol; Sylvia J W Kunst; Ad F M Snik; Cor W R J Cremers
Journal:  Eur Arch Otorhinolaryngol       Date:  2009-11-11       Impact factor: 2.503

10.  Toward Optimal Care for Children With Congenital Unilateral Aural Atresia.

Authors:  Filip Asp; Robert J Stokroos; Martijn J H Agterberg
Journal:  Front Neurol       Date:  2021-07-08       Impact factor: 4.003

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.