Literature DB >> 11464766

HACCP (Hazard Analysis and Critical Control Points) to guarantee safe water reuse and drinking water production--a case study.

T Dewettinck1, E Van Houtte, D Geenens, K Van Hege, W Verstraete.   

Abstract

To obtain a sustainable water catchment in the dune area of the Flemish west coast, the integration of treated domestic wastewater in the existing potable water production process is planned. The hygienic hazards associated with the introduction of treated domestic wastewater into the water cycle are well recognised. Therefore, the concept of HACCP (Hazard Analysis and Critical Control Points) was used to guarantee hygienically safe drinking water production. Taking into account the literature data on the removal efficiencies of the proposed advanced treatment steps with regard to enteric viruses and protozoa and after setting high quality limits based on the recent progress in quantitative risk assessment, the critical control points (CCPs) and points of attention (POAs) were identified. Based on the HACCP analysis a specific monitoring strategy was developed which focused on the control of these CCPs and POAs.

Entities:  

Mesh:

Year:  2001        PMID: 11464766

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  4 in total

1.  Composition and dynamics of bacterial communities of a drinking water supply system as assessed by RNA- and DNA-based 16S rRNA gene fingerprinting.

Authors:  Stefan Eichler; Richard Christen; Claudia Höltje; Petra Westphal; Julia Bötel; Ingrid Brettar; Arndt Mehling; Manfred G Höfle
Journal:  Appl Environ Microbiol       Date:  2006-03       Impact factor: 4.792

2.  Campylobacter spp., Giardia spp., Cryptosporidium spp., noroviruses, and indicator organisms in surface water in southwestern Finland, 2000-2001.

Authors:  Ari Hörman; Ruska Rimhanen-Finne; Leena Maunula; Carl-Henrik von Bonsdorff; Niina Torvela; Annamari Heikinheimo; Marja-Liisa Hänninen
Journal:  Appl Environ Microbiol       Date:  2004-01       Impact factor: 4.792

Review 3.  HACCP-Based Programs for Preventing Disease and Injury from Premise Plumbing: A Building Consensus.

Authors:  William F McCoy; Aaron A Rosenblatt
Journal:  Pathogens       Date:  2015-07-09

Review 4.  Indirect potable reuse: a sustainable water supply alternative.

Authors:  Clemencia Rodriguez; Paul Van Buynder; Richard Lugg; Palenque Blair; Brian Devine; Angus Cook; Philip Weinstein
Journal:  Int J Environ Res Public Health       Date:  2009-03-17       Impact factor: 3.390

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.