Literature DB >> 11462298

Pharmacokinetics of echocontrast agent infusion in a dog model.

M Kaps1, G Seidel, C Algermissen, T Gerriets, A Broillet.   

Abstract

Ultrasound contrast agents (UCAs) have a distinct diagnostic impact on transcranial Doppler (TCD) and duplex sonography. In addition to the properties of the UCA and ultrasound imaging modes, the duration of contrast enhancement depends on the administration mode. Infusion of UCAs may be appropriate for prolonging the diagnostically useful time of elevated Doppler intensity. Five sedated dogs were investigated by TCD during infusion with SonoVue, a new UCA consisting of sulfur hexafluoride microbubbles. The infusion rate was varied, and the time-intensity curves were analyzed. Infusion rate of 70 ml/h provided a stable mean level of increased Doppler intensity up to 24 to 26 dB over baseline, whereas a rate of 35 ml/h did not result in a stable plateau (range 8-19 dB over baseline [5 minutes after starting time]). The maximum increases in Doppler mean intensity (18.2 dB [35 ml/h] and 25.6 dB [70 ml/h]) were significantly different (P = .025). Pharmacokinetic analysis of SonoVue during inflow (by exponential functional fitting of the time-mean intensity curves) and elimination (by linear regression analysis) revealed no dose-related differences. This study demonstrated a dose-dependent level of increased Doppler mean intensity within the brain circulation during infusion of SonoVue. Unlike the bell-shaped course of Doppler signal enhancement seen after bolus injection, infusion generates a stable plateau, which is an important prerequisite for more advanced contrast applications.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11462298     DOI: 10.1111/j.1552-6569.2001.tb00050.x

Source DB:  PubMed          Journal:  J Neuroimaging        ISSN: 1051-2284            Impact factor:   2.486


  3 in total

Review 1.  Ultrasound-induced blood-brain barrier opening.

Authors:  Elisa E Konofagou; Yao-Sheng Tung; James Choi; Thomas Deffieux; Babak Baseri; Fotios Vlachos
Journal:  Curr Pharm Biotechnol       Date:  2012-06       Impact factor: 2.837

2.  In vivo gas body efficacy for glomerular capillary hemorrhage induced by diagnostic ultrasound in rats.

Authors:  Douglas L Miller; Chunyan Dou; Roger C Wiggins
Journal:  IEEE Trans Biomed Eng       Date:  2009-08-25       Impact factor: 4.538

3.  Optimization of the ultrasound-induced blood-brain barrier opening.

Authors:  Elisa E Konofagou
Journal:  Theranostics       Date:  2012-12-31       Impact factor: 11.556

  3 in total