Literature DB >> 11460583

Recent advances in continuous glucose monitoring.

G Freckmann1, B Kalatz, B Pfeiffer, U Hoss, C Haug.   

Abstract

Continuous glucose monitoring, providing more detailed information on glucose excursions than single spot measurements, should help to improve the therapy in diabetic patients and is also required for feedback-controlled insulin delivery. At the Institute for Diabetes-Technology in Ulm, founded by EF Pfeiffer, a portable glucose sensor for continuous tissue glucose monitoring has been developed. The combination of microdialysis and enzymatic amperometric glucose measurement implemented in this device marked a break-through in achieving reliable and precise continuous tissue glucose monitoring. In several studies, we have demonstrated that continuous subcutaneous glucose monitoring for up to 72 hours is feasible under 'in-house' and 'daily life' conditions in diabetic patients. The measured tissue glucose concentrations correlated closely to glucose control measurements in venous and capillary blood. A reliable continuous glucose monitoring device is a prerequisite for the development of an artificial pancreas. Our group developed an algorithm for subcutaneous application of the fast acting insulin analogon lispro. In experiments performed over 7 and 24 hours good metabolic control was achieved by algorithm-based insulin application. In addition, the algorithm was able to maintain acceptable metabolic control during and after moderate physical exercise. Further work is needed to optimize continuous tissue glucose monitoring systems and to develop a closed loop system for insulin application based on continuously measured tissue glucose concentrations.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11460583     DOI: 10.1055/s-2001-18594

Source DB:  PubMed          Journal:  Exp Clin Endocrinol Diabetes        ISSN: 0947-7349            Impact factor:   2.949


  7 in total

1.  A switching control strategy for the attenuation of blood glucose disturbances.

Authors:  Mihalis G Markakis; Georgios D Mitsis; George P Papavassilopoulos; Petros A Ioannou; Vasilis Z Marmarelis
Journal:  Optim Control Appl Methods       Date:  2011       Impact factor: 2.530

Review 2.  Microdialysis as a tool in local pharmacodynamics.

Authors:  Yanjun Li; Joanna Peris; Li Zhong; Hartmut Derendorf
Journal:  AAPS J       Date:  2006-04-07       Impact factor: 4.009

3.  Feasibility of overnight closed-loop control based on hourly blood glucose measurements.

Authors:  Caroline Patte; Stefan Pleus; Paul Galley; Stefan Weinert; Cornelia Haug; Guido Freckmann
Journal:  J Diabetes Sci Technol       Date:  2012-07-01

4.  Use of microdialysis-based continuous glucose monitoring to drive real-time semi-closed-loop insulin infusion.

Authors:  Guido Freckmann; Nina Jendrike; Stefan Pleus; Harvey Buck; Steven Bousamra; Paul Galley; Ajay Thukral; Robin Wagner; Stefan Weinert; Cornelia Haug
Journal:  J Diabetes Sci Technol       Date:  2014-09-09

5.  Novel insulin delivery profiles for mixed meals for sensor-augmented pump and closed-loop artificial pancreas therapy for type 1 diabetes mellitus.

Authors:  Asavari Srinivasan; Joon Bok Lee; Eyal Dassau; Francis J Doyle
Journal:  J Diabetes Sci Technol       Date:  2014-07-21

6.  The artificial pancreas: how sweet engineering will solve bitter problems.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2007-01

7.  Nonlinear modeling of the dynamic effects of infused insulin on glucose: comparison of compartmental with Volterra models.

Authors:  Georgios D Mitsis; Mihalis G Markakis; Vasilis Z Marmarelis
Journal:  IEEE Trans Biomed Eng       Date:  2009-06-02       Impact factor: 4.538

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.