Literature DB >> 11459619

Diagnostic yield of the lactate stress test in respiratory chain disorders under absolute and relative workload.

J Finsterer1, E Milvay.   

Abstract

Usually, the lactate stress test is carried under a constant, low workload maintained for 15 min, although there are indications that the lactate response to exercise is a function of the relative workload, and that a workload for only 5 min does not decrease its sensitivity. Thus, this study compared the diagnostic yield of the lactate stress test when carried out under a constant workload of 30 W (LSTA) and under a workload of 30% of maximum (LSTR), and when the workload was maintained for 5 and 15 min. In 16 patients with respiratory chain disorders, 12 women, four men, aged 27--88 years, the LSTA and LSTR were carried out on 2 different days, within 48 h. For both tests serum lactate was determined before, during and after a 15-min workload on a bicycle. Upper reference limits at rest, 5, 10, 15 min after starting, and 15 min after finishing the exercise were 1.9, 2.0, 2.0, 2.0, and 1.6 mmol/l for the LSTA, and 2.3, 3.0, 3.2, 3.4 and 2.7 mmol/l for the LSTR. The sensitivity was 88% for the LSTA and 63% for the LSTR. The specificity of the LSTA was 94%. The diagnostic yield of both tests was similar when the workload was maintained for 5 or 15 min. In conclusion, the LSTA should be preferred to the LSTR. Three lactate determinations during 15 min have no advantage over a single lactate determination after a 5 min workload of 30 W.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11459619     DOI: 10.1016/s0165-0270(01)00371-5

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  5 in total

Review 1.  Metabolic myopathies: functional evaluation by different exercise testing approaches.

Authors:  L Volpi; G Ricci; D Orsucci; R Alessi; F Bertolucci; S Piazza; C Simoncini; M Mancuso; G Siciliano
Journal:  Musculoskelet Surg       Date:  2011-03-04

2.  Lactate increase and oxygen desaturation in mitochondrial disorders--evaluation of two diagnostic screening protocols.

Authors:  Frank Hanisch; Tobias Müller; Anett Muser; Marcus Deschauer; Stephan Zierz
Journal:  J Neurol       Date:  2006-04-20       Impact factor: 4.849

3.  Lactate stress testing by bedside lactate determination.

Authors:  Josef Finsterer
Journal:  Metab Brain Dis       Date:  2003-12       Impact factor: 3.584

4.  Abnormal Lactate Levels Affect Motor Performance in Myotonic Dystrophy Type 1.

Authors:  Caterina Tramonti; Stefania Dalise; Federica Bertolucci; Bruno Rossi; Carmelo Chisari
Journal:  Eur J Transl Myol       Date:  2014-12-24

5.  Diagnostic Values of Venous Peak Lactate, Lactate-to-pyruvate Ratio, and Fold Increase in Lactate from Baseline in Aerobic Exercise Tests in Patients with Mitochondrial Diseases.

Authors:  Masanori Kurihara; Yusuke Sugiyama; Masaki Tanaka; Kenichiro Sato; Akihiko Mitsutake; Hiroyuki Ishiura; Akatsuki Kubota; Kaori Sakuishi; Toshihiro Hayashi; Atsushi Iwata; Jun Shimizu; Kei Murayama; Shoji Tsuji; Tatsushi Toda
Journal:  Intern Med       Date:  2021-11-27       Impact factor: 1.282

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.