Literature DB >> 11455381

Comparison of ion release from new and recycled orthodontic brackets.

T H Huang1, C C Yen, C T Kao.   

Abstract

Bracket corrosion can occur in the oral environment. The purpose of this study was to compare the release of metal ions from new and recycled brackets in artificial saliva and buffers with different pH values over a 12-week immersion period. The brackets were divided into 2 groups: new and recycled. The recycled bracket bases were coated with adhesive and the brackets were heat treated. Nickel, chromium, iron, and manganese ions were detected by atomic absorption. The surface characteristics of the brackets were examined by energy dispersive radiographic analysis. The results were as follows: (1) Recycled brackets released more ions than did the new brackets. (2) Greater amounts of nickel, iron, and manganese ions were released in artificial saliva than in the other buffers tested. (3) Ion release from brackets in a pH 4 buffer was greater than that observed in pH 7 or pH 10 buffers. (4) The total amount of ion release increased with time. (5) After a 12-week immersion, the total ion release averaged over the period did not exceed the recommended daily intake.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11455381     DOI: 10.1067/mod.2001.113794

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  9 in total

1.  SBS vs Inhouse Recycling Methods-An Invitro Evaluation.

Authors:  Supradeep Kumar Kamisetty; Jaya Krishanan Verma; Shanta Sundari; Shyamala Chandrasekhar; Aravind Kumar
Journal:  J Clin Diagn Res       Date:  2015-09-01

2.  Reconditioning of self-ligating brackets.

Authors:  Maria Francesca Sfondrini; Esmeralda Xheka; Andrea Scribante; Paola Gandini; Giuseppe Sfondrini
Journal:  Angle Orthod       Date:  2011-08-01       Impact factor: 2.079

3.  Estimation of Release of Nickel and Chromium by Indian Made Orthodontic Appliance in Saliva.

Authors:  Sandeep Parashar; Rajkumar Maurya; Ankur Gupta; Chatura Hegde; Neelima Anand
Journal:  J Clin Diagn Res       Date:  2015-09-01

4.  Recycling stainless steel orthodontic brackets with Er:YAG laser - An environmental scanning electron microscope and shear bond strength study.

Authors:  Prince K Chacko; Jithesh Kodoth; Jacob John; Kishore Kumar
Journal:  J Orthod Sci       Date:  2013-07

5.  Evaluation of the Corrosion of Five Different Bracket-Archwire Combination: An In-vitro Analysis Using Inductively Coupled Plasma Mass Spectrometry.

Authors:  Zeinab Behroozi; Shahla Momeni Danaei; Ali Reza Sardarian; Vahid Moshkelghosha; Ahmad Reza Sardarian
Journal:  J Dent (Shiraz)       Date:  2016-09

6.  Metal release profiles of orthodontic bands, brackets, and wires: an in vitro study.

Authors:  B Wendl; H Wiltsche; E Lankmayr; H Winsauer; A Walter; A Muchitsch; N Jakse; M Wendl; T Wendl
Journal:  J Orofac Orthop       Date:  2017-09-14       Impact factor: 1.938

7.  Release of nickel and chromium ions in the saliva of patients with fixed orthodontic appliance: An in-vivo study.

Authors:  Anoop Dwivedi; Tripti Tikku; Rohit Khanna; Rana Pratap Maurya; Geeta Verma; R C Murthy
Journal:  Natl J Maxillofac Surg       Date:  2015 Jan-Jun

8.  Comparison of Galvanic Currents Generated Between Different Combinations of Orthodontic Brackets and Archwires Using Potentiostat: An In Vitro Study.

Authors:  Rabindra S Nayak; Bareera Shafiuddin; Azam Pasha; K Vinay; Anjali Narayan; Smitha V Shetty
Journal:  J Int Oral Health       Date:  2015-07

9.  Comparative evaluation of nickel discharge from brackets in artificial saliva at different time intervals.

Authors:  C Jithesh; V Venkataramana; Narendravarma Penumatsa; S N Reddy; K Y Poornima; K Rajasigamani
Journal:  J Pharm Bioallied Sci       Date:  2015-08
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.