Literature DB >> 11454282

Protocol for X-ray dosimetry in radiobiology.

J Zoetelief1, J J Broerse, R W Davies, M Octave-Prignot, M Rezvani, J C Vergara, M P Toni.   

Abstract

PURPOSE: To harmonize X-ray dosimetry in radiobiology to allow a direct comparison of radiobiological studies performed at institutes cooperating within the framework of the European Late Effects Project Group (EULEP).
MATERIALS AND METHODS: The 1985 EULEP protocol for X-ray dosimetry and exposure arrangements employed for studies of late somatic effects in mammals required serious revision, e.g. due to the replacement of calibration of dosemeters in terms of exposure by calibration in terms of air kerma free-in-air. An action group established by EULEP and the European Radiation Dosimetry Group (EURADOS) updated the 1985 protocol.
RESULTS: The new EULEP-EURADOS protocol for X-ray dosimetry in radiobiology including the code of practice for irradiation of small animals and related dosimetry. The present protocol includes the changes in calibration procedures and dosimetric concepts for irradiation with medium energy X-rays since 1985. Accuracy and precision are replaced by the concept of combined (standard) uncertainty. The revised supplements provide more detailed background information. New appendices contain definitions of general terms used for measurements and mathematical expressions of the relative variances.
CONCLUSION: Adherence to the present protocol will result in improved dosimetry and facilitates the comparison of results of radiobiological experiments obtained at different institutes.

Entities:  

Mesh:

Year:  2001        PMID: 11454282     DOI: 10.1080/09553000110050605

Source DB:  PubMed          Journal:  Int J Radiat Biol        ISSN: 0955-3002            Impact factor:   2.694


  6 in total

1.  Dosimetry Formalism and Implementation of a Homogenous Irradiation Protocol to Improve the Accuracy of Small Animal Whole-Body Irradiation Using a 137Cs Irradiator.

Authors:  N Patrik Brodin; Yong Chen; Ravindra Yaparpalvi; Chandan Guha; Wolfgang A Tomé
Journal:  Health Phys       Date:  2016-02       Impact factor: 1.316

2.  An interlaboratory comparison of dosimetry for a multi-institutional radiobiological research project: Observations, problems, solutions and lessons learned.

Authors:  Thomas M Seed; Shiyun Xiao; Nancy Manley; Janko Nikolich-Zugich; Jason Pugh; Marcel Van den Brink; Yoko Hirabayashi; Koji Yasutomo; Atsushi Iwama; Shigeo Koyasu; Ivo Shterev; Gregory Sempowski; Francesca Macchiarini; Kei Nakachi; Keith C Kunugi; Clifford G Hammer; Lawrence A Dewerd
Journal:  Int J Radiat Biol       Date:  2015-11-17       Impact factor: 2.694

3.  Dose Variations Using an X-Ray Cabinet to Establish in vitro Dose-Response Curves for Biological Dosimetry Assays.

Authors:  Martin Bucher; Tina Weiss; David Endesfelder; Francois Trompier; Yoann Ristic; Patrizia Kunert; Helmut Schlattl; Augusto Giussani; Ursula Oestreicher
Journal:  Front Public Health       Date:  2022-05-17

4.  Commissioning and evaluation of a new commercial small rodent x-ray irradiator.

Authors:  Mk Woo; Ra Nordal
Journal:  Biomed Imaging Interv J       Date:  2006-01-01

5.  Chemokine-like receptor 1 deficiency does not affect the development of insulin resistance and nonalcoholic fatty liver disease in mice.

Authors:  Nanda Gruben; Marcela Aparicio Vergara; Niels J Kloosterhuis; Henk van der Molen; Stefan Stoelwinder; Sameh Youssef; Alain de Bruin; Dianne J Delsing; Jan Albert Kuivenhoven; Bart van de Sluis; Marten H Hofker; Debby P Y Koonen
Journal:  PLoS One       Date:  2014-04-29       Impact factor: 3.240

Review 6.  Preclinical Data on Efficacy of 10 Drug-Radiation Combinations: Evaluations, Concerns, and Recommendations.

Authors:  Helen B Stone; Eric J Bernhard; C Norman Coleman; James Deye; Jacek Capala; James B Mitchell; J Martin Brown
Journal:  Transl Oncol       Date:  2016-02       Impact factor: 4.243

  6 in total