Literature DB >> 11453879

Heparin-coated extracorporeal circulation with full and low dose heparinization: comparison of thrombin related coagulatory effects.

N Mirow1, T Brinkmann, K Minami, G Tenderich, K Kleesiek, R Körfer.   

Abstract

Thrombin related coagulatory effects of a heparin-coated cardiopulmonary bypass system combined with full and low dose systemic heparinization were investigated in a prospective, randomized study in coronary bypass surgery patients. One hundred nineteen patients were divided into 3 groups. Group A (n = 39) had a standard uncoated extracorporeal circulation (ECC) set, and systemic heparin was administered in an initial dose of 400 IU/kg body weight. During ECC activated clotting time (ACT) was maintained at > or =480 s. Group B (n = 42) had the same ECC set completely coated with low molecular weight heparin. Intravenous heparin was given in the same dose as in Group A, and ACT was kept at the same level. Group C (n = 38) had the same coated ECC set as Group B, but intravenous heparin was reduced to 150 IU/kg, and during ECC, ACT was set to be > or =240 s. The same ECC components were used in all 3 groups including roller pumps, coronary suction, and an open cardiotomy reservoir. Thrombin generation as indicated by F1/F2 was significantly elevated at an ECC duration >60 min if heparin-coated ECC combined with low dose systemic heparinization was employed. Complexed thrombin (TAT) was significantly elevated after administration of protamine. Release of D-dimers indicating fibrinolysis was not significantly different between groups. Signs of clinical thromboembolism, i.e., postoperative neurological deficit, occurred in 2 patients in Group A and 1 patient in Group C. We conclude that heparin-coated extracorporeal circulation combined with reduced systemic heparinization intraoperatively leads to significantly increased thrombin generation, but not to increased fibrinolysis.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11453879     DOI: 10.1046/j.1525-1594.2001.025006480.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  2 in total

1.  Heparin reduction with the use of cardiotomy suction is associated with hyperfibrinolysis during distal aortic perfusion with a heparin-coated semi-closed cardiopulmonary bypass system.

Authors:  Norihiko Shiiya; Kenji Matsuzaki; Takashi Kunihara; Hiroshi Sugiki
Journal:  J Artif Organs       Date:  2006-12-21       Impact factor: 1.731

2.  A randomized study of coronary artery bypass surgery performed with the Resting Heart™ System utilizing a low vs a standard dosage of heparin.

Authors:  Johan Nilsson; Sara Scicluna; Gunnar Malmkvist; Leif Pierre; Lars Algotsson; Per Paulsson; Henrik Bjursten; Per Johnsson
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-08-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.