The effect of circuit surface area on CD11b(mac-1) expression in a rat recirculation model.

T Gourlay1, D C Stefanou, G Asimakopoulos, K M Taylor.   

Abstract

The aim of the study was to assess the effect of exposed surface area of diethylhexylphthalate plasticized polyvinylchloride (PVC) on the expression of the adhesion molecule CD11b(mac-1) on neutrophils and to determine whether there is any apparent advantage in the current trend in reducing circuit surface area in terms of neutrophil activation. The study was carried out using a parallel plate rodent recirculation biomaterial testing model on 4 groups of 10 adult male Sprague Dawley rats weighing between 350 and 450 g. One group comprised the control group in which there was no biomaterial exposure. In the remaining 3 groups, the animals were subjected to either high (48 cm2), intermediate (24 cm2), or low (12 cm2) biomaterial surface area exposure. The parallel plate test cell was connected to the right femoral circulation and recirculation initiated at a flow rate of 1.5 ml/min for a period of 60 min. Blood samples were taken at 0, 30, and 60 min for the assessment of CD11b expression. Cd11b was assessed using flow cytometric analysis on neutrophils. The results demonstrated that there was a surface area related effect in the upregulation of CD11b. The difference at the terminal sample point between the highest surface area group (293.95 +/- 18.57%) and the low surface area group (133.80 +/- 49.31%) was highly statistically significant (p < 0.001). These results demonstrate that there may be some gain in terms of reduced inflammatory response from reducing the exposed surface area of PVC in extracorporeal perfusion circuits.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11453878     DOI: 10.1046/j.1525-1594.2001.025006475.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

1.  Phthalates in food and medical devices.

Authors:  Karen Chou; Robert O Wright
Journal:  J Med Toxicol       Date:  2006-09

2.  The effect of priming solutions and storage time on plasticizer migration in different PVC tubing types--implications for wet storage of ECMO systems.

Authors:  David C Horne; Ida Torrance; Thomas Modine; Terence Gourlay
Journal:  J Extra Corpor Technol       Date:  2009-12

3.  Ex-Vivo Uterine Environment (EVE) Therapy Induced Limited Fetal Inflammation in a Premature Lamb Model.

Authors:  Yuichiro Miura; Masatoshi Saito; Haruo Usuda; Eleanor Woodward; Judith Rittenschober-Böhm; Paranthaman S Kannan; Gabrielle C Musk; Tadashi Matsuda; John P Newnham; Matthew W Kemp
Journal:  PLoS One       Date:  2015-10-16       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.