Literature DB >> 11453054

99Tc(m)-tetrofosmin scintimammography for detecting breast cancer: a comparative study with 99Tc(m)-MIBI.

T Horne1, I Pappo, M Cohen-Pour, M Baumer, R Orda.   

Abstract

Scintimammography using 99Tc(m)-MIBI (99Tc(m)-sestamibi) has demonstrated promising results in the detection of breast cancer. Recently scintimammography using 99Tc(m)-tetrofosmin has been suggested as a better diagnostic tool and a more convenient agent to use in this condition. In this study we compared both agents in 35 consecutive women with abnormal mammographic or physical findings. Thirty-four of them underwent MIBI scan, followed by tetrofosmin scan 2 days later (performed on all 35 women). Within 2 weeks, a pathological diagnosis was obtained either by needle or open biopsy. In both scans the uptake ratio between the lesion and the background uptake was calculated. Twenty patients who underwent tetrofosmin scan and 19 patients with MIBI scan had malignant breast tumours, while 15 women had benign lesions. The sensitivity, specificity, positive and negative predictive values and total accuracy of the MIBI scan were 89.4%, 80%, 85%, 85.7% and 85.3%, respectively; almost identical values were obtained with tetrofosmin (90%, 80%, 85.6%, 85.7% and 85.7%, respectively). The uptake ratios in the MIBI and tetrofosmin scans were 1.68 +/- 0.52 and 1.7 +/- 0.47, respectively. No differences were found between the two scintimammographies in all the parameters examined. In conclusion, MIBI and tetrofosmin breast scans are accurate and equally efficient for the detection of breast malignancies.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11453054     DOI: 10.1097/00006231-200107000-00012

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  7 in total

1.  Breast scintigraphy: procedure guidelines for tumour imaging.

Authors:  Emilio Bombardieri; Cumali Aktolun; Richard P Baum; Angelika Bishof-Delaloye; John Buscombe; Jean François Chatal; Lorenzo Maffioli; Roy Moncayo; Luc Mortelmans; Sven N Reske
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-12       Impact factor: 9.236

2.  Screening for breast cancer should be an integral part of myocardial perfusion imaging.

Authors:  Jean Lette; François Lette
Journal:  Can J Cardiol       Date:  2009-07       Impact factor: 5.223

3.  Functional Radionuclide Imaging, In-Vitro Radioiodine Uptake Estimation and RT-PCR in the Evaluation of Sodium Iodide Symporter (NIS) Expression and Functionality in Breast Cancer: A Pilot Study.

Authors:  J K Joseph; R B Patel; A A Damle; N Nair; R A Badwe; S Basu
Journal:  Indian J Surg Oncol       Date:  2013-01-05

4.  Quantification of lesion size, depth, and uptake using a dual-head molecular breast imaging system.

Authors:  Carrie B Hruska; Michael K O'Connor
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

5.  Planar Tc99m--sestamibi scintimammography should be considered cautiously in the axillary evaluation of breast cancer protocols: results of an international multicenter trial.

Authors:  Teresa Massardo; Omar Alonso; Augusto Llamas-Ollier; Levin Kabasakal; Uma Ravishankar; Rossana Morales; Lucía Delgado; Ajit K Padhy
Journal:  BMC Nucl Med       Date:  2005-07-27

Review 6.  Breast-Specific Gamma Imaging: An Added Value in the Diagnosis of Breast Cancer, a Systematic Review.

Authors:  Maria Silvia De Feo; Marko Magdi Abdou Sidrak; Miriam Conte; Viviana Frantellizzi; Andrea Marongiu; Flaminia De Cristofaro; Susanna Nuvoli; Angela Spanu; Giuseppe De Vincentis
Journal:  Cancers (Basel)       Date:  2022-09-23       Impact factor: 6.575

7.  Study of the cytotoxicity of asiaticoside on rats and tumour cells.

Authors:  Fatma J Al-Saeedi
Journal:  BMC Cancer       Date:  2014-03-25       Impact factor: 4.430

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.