| Literature DB >> 11451653 |
T Ding1, S Tian, Z Zhang, D Gu, Y Chen, Y Shi, Z Sun.
Abstract
Silybin, isosilybin, silydianin and silycristin in silymarin were separated and quantitatively determined by RP-HPLC. Two diastereoisomers of silybin and isosilybin were respectively separated by RP-HPLC and confirmed by LC/MS. Chromatographic condition consisted of column: Shim-pack VP-ODS (150 x 4.6mm i.d. 5 microm) and Pre-column (10 x 4.6 mm i.d. 5 microm); mobile phase: methanol and solvent mixture (water: dioxane=9:1) by gradient; flow rate: 1.5ml/min; column temp.: 40 degrees C; detector wavelength: 288 nm; The recovery of 99.66% for silycristin, 99.48% for silydianin, 100.0% for silybin and 98.72% for isosilybin was respectively obtained.Entities:
Mesh:
Substances:
Year: 2001 PMID: 11451653 DOI: 10.1016/s0731-7085(01)00364-8
Source DB: PubMed Journal: J Pharm Biomed Anal ISSN: 0731-7085 Impact factor: 3.935