Total knee arthroplasty with 4.4 mm of tibial polyethylene: 10-year followup.

J B Meding1, M A Ritter, P M Faris.   

Abstract

A consecutive series of 387, one-piece, 8-mm tibial components were implanted in 313 patients. All tibial prostheses were manufactured with 4.4 mm of polyethylene directly molded to a 3.6 mm cobalt chrome metal baseplate. The average age of the patients at surgery was 70.6 years. From this group, a subset of 116 patients underwent bilateral total knee arthroplasties with an 8-mm tibial component on one side and at least a 10-mm thick tibial component (at least 6.4 mm of polyethylene) on the other side. The followup averaged 10.7 years. Postoperative knee and pain scores average 81.4 points and 47.2 points, respectively. No radiographic polyethylene wear or osteolytic lesions were identified. Tibial radiolucencies were observed in four knees. There were nine failures (2.3%). Three knees were revised for infection. Five knees were revised for metallosis secondary to failure of metal-backed patellas. No loose tibial components were identified. Defining failure as revision for any reason or loosening of any component, Kaplan-Meier survival rates at 5, 10, and 15 years were 98.7%, 95.4%, and 94.3%, respectively. There was no significant difference in clinical scores or survival rates between the knee components with thicker (at least 6.4 mm) or thinner (4.4 mm) polyethylene.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11451109     DOI: 10.1097/00003086-200107000-00017

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  3 in total

Review 1.  Validity of published outcome data concerning Anatomic Graduated Component total knee arthroplasty: a structured literature review including arthroplasty register data.

Authors:  Reinhard Schuh; Gerald Dorninger; Mark Agreiter; Nikolaus Boehler; Gerold Labek
Journal:  Int Orthop       Date:  2011-04-13       Impact factor: 3.075

2.  Segmental cement extraction system (SEG-CES) and the Ilizarov method in limb salvage procedure after total knee cemented prosthesis removal in a former osteosarcoma patient.

Authors:  Giulia Ottaviani; Pietro Randelli; Maurizio A Catagni
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-01-20       Impact factor: 4.342

3.  Polyethylene thickness is a risk factor for wear necessitating insert exchange.

Authors:  Bart G Pijls; Henrica M J Van der Linden-Van der Zwaag; Rob G H H Nelissen
Journal:  Int Orthop       Date:  2011-11-22       Impact factor: 3.075

  3 in total