Ultrasonic backscatter and transmission parameters at the os calcis in postmenopausal osteoporosis.

C Roux1, V Roberjot, R Porcher, S Kolta, M Dougados, P Laugier.   

Abstract

Ultrasound technology has emerged as a new tool in the assessment of osteoporosis. Ultrasound parameters usually are measured in transmission; there is a potential for the analysis of backscattered signals to provide information on bone microarchitecture. The aim of this study was to explore a new technological development of the method, adding backscatter coefficient to transmission parameters, and to examine the appropriate thresholds to identify postmenopausal osteoporotic women. We examined 210 postmenopausal women (including 60 with osteoporotic fractures) and 30 healthy premenopausal controls. They had lumbar spine and hip bone mineral density (BMD) measurement and quantitative ultrasound (QUS) evaluation at the os calcis, measured in transmission (broadband ultrasound attenuation [BUA], speed of sound [SOS], ratio of transit time [dt] to BUA [dt/BUA], and "strength" index [STI]) and reflexion (broadband ultrasound backscattering [BUB]). The standardized CVs (sCVs) were between 2.27 % and 3.40 % for QUS measured in transmission and 4.41% for BUB. The odds ratio (OR) for fracture discrimination adjusted for age was 2.77 for hip BMD and between 1.6 and 2.9 for QUS. After adjustment for hip BMD, ORs were still highly significant for SOS, STI, and dt/BUA. According to hip BMD T score, prevalence of osteoporosis in our population was 39%. To detect the same prevalence, T scores ranged between -0.95 and -1.42 for QUS. QUS parameters have adequate ability to discriminate osteoporotic patients from controls. The World Health Organization (WHO) threshold for diagnosis of osteoporosis does not apply to this technology. The clinical utility of BUB at the os calcis, in addition to usual ultrasound parameters, is not yet proven. However, BUB evaluation, which does not require two transducers and may be implemented in conventional reflection mode systems, warrants further studies.

Entities:  

Mesh:

Year:  2001        PMID: 11450712     DOI: 10.1359/jbmr.2001.16.7.1353

Source DB:  PubMed          Journal:  J Bone Miner Res        ISSN: 0884-0431            Impact factor:   6.741


  18 in total

1.  The effect of trabecular material properties on the frequency dependence of backscatter from cancellous bone.

Authors:  Keith A Wear
Journal:  J Acoust Soc Am       Date:  2003-07       Impact factor: 1.840

2.  The dependence of ultrasonic backscatter on trabecular thickness in human calcaneus: theoretical and experimental results.

Authors:  Keith A Wear; Andres Laib
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-08       Impact factor: 2.725

3.  Relationships of quantitative ultrasound parameters with cancellous bone microstructure in human calcaneus in vitro.

Authors:  Keith A Wear; Srinidhi Nagaraja; Maureen L Dreher; Sheng L Gibson
Journal:  J Acoust Soc Am       Date:  2012-02       Impact factor: 1.840

4.  Effect of intervening tissues on ultrasonic backscatter measurements of bone: An in vitro study.

Authors:  Brent K Hoffmeister; P Luke Spinolo; Mark E Sellers; Peyton L Marshall; Ann M Viano; Sang-Rok Lee
Journal:  J Acoust Soc Am       Date:  2015-10       Impact factor: 1.840

5.  Correlation between the combination of apparent integrated backscatter-spectral centroid shift and bone mineral density.

Authors:  Tao Tang; Chengcheng Liu; Feng Xu; Dean Ta
Journal:  J Med Ultrason (2001)       Date:  2016-01-11       Impact factor: 1.314

6.  Characterization of the trabecular bone structure using frequency modulated ultrasound pulse.

Authors:  Wei Lin; Yi Xia; Yi-Xian Qin
Journal:  J Acoust Soc Am       Date:  2009-06       Impact factor: 1.840

7.  Mechanisms for attenuation in cancellous-bone-mimicking phantoms.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-11       Impact factor: 2.725

Review 8.  Ultrasonic scattering from cancellous bone: a review.

Authors:  K A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-07       Impact factor: 2.725

Review 9.  Clinical Evaluation of Bone Strength and Fracture Risk.

Authors:  Chantal M J de Bakker; Wei-Ju Tseng; Yihan Li; Hongbo Zhao; X Sherry Liu
Journal:  Curr Osteoporos Rep       Date:  2017-02       Impact factor: 5.096

10.  Relationships among ultrasonic and mechanical properties of cancellous bone in human calcaneus in vitro.

Authors:  Keith A Wear; Srinidhi Nagaraja; Maureen L Dreher; Saghi Sadoughi; Shan Zhu; Tony M Keaveny
Journal:  Bone       Date:  2017-06-27       Impact factor: 4.398

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.