H Kado1, H Iida, H Kimura, T Ogawa, Y Narita, J Hatazawa, T Tsuchida, Y Yonekura, H Itoh.
Abstract
To evaluate the usefulness of a combination of linearization and scatter-attenuation correction on 99mTc-bicisate (ECD)-single photon emission tomographic (SPECT) images, both cerebral blood flow (CBF)-positron emission tomographic (PET) images and ECD-SPECT images from fifteen patients with chronic cerebral infarction were acquired. We measured radioactivity counts in regions of interest (ROIs) on all sets of both images and obtained a 2D scattered graph between ECD-SPECT and CBF-PET data. To evaluate diagnostic accuracy, the sensitivity, specificity and accuracy of ECD-SPECT images were calculated by means of discriminant analysis. The same analysis was also performed on the ECD-SPECT images corrected by a combination of linearization and scatter-attenuation correction. An overall nonlinear relationship was observed between ECD-SPECT and CBF-PET. The sensitivity, specificity, and accuracy of ECD-SPECT images were 69.6%, 91.4% and 73.0%, and those of ECD images corrected by the combination of linearization and scatter-attenuation correction were 79.5%, 95.7% and 82.0% respectively. The clinically diagnostic accuracy of ECD-SPECT images corrected by the combined method apparently increased. So that the linearization with the scatter-attenuation method is useful for improving the diagnostic accuracy of ECD-SPECT images.Entities:
Mesh:
Substances:
Year: 2001 PMID: 11448070 DOI: 10.1007/BF02988602
Source DB: PubMed Journal: Ann Nucl Med ISSN: 0914-7187 Impact factor: 2.668