Abstract

OBJECTIVES: The purpose of this study is to investigate the effect of remaining dentin thickness and the use of a 20% polyalkenoic acid conditioner on the micro-tensile bond strength of a glass-ionomer adhesive to dentin.
METHODS: Resin composite was bonded to flat dentin surfaces from 14 extracted human teeth using Fuji BOND LC (GC) with or without a polyalkenoic acid conditioner, then sectioned to thin slabs, trimmed into an hourglass shape with the area of the interface being approximately 1mm(2), and subjected to micro-tensile testing at a cross-head speed of 1mm/min. Micro-tensile bond strengths were determined at three depth levels with a remaining dentin thickness of more than 3mm, between 2 and 3mm, and less than 2mm. Failure modes of the broken interfaces were determined using field-emission scanning electron microscopy.
RESULTS: The micro-tensile bond strength to dentin significantly improved when the remaining dentin thickness increased and the conditioner was used. When the conditioner was used (irrespective of remaining dentin thickness), failures mainly occurred adhesively at the interface between the adhesive and resin composite. When no conditioner was used, no adhesive failures between the adhesive and resin composite occurred, but failures occurred mainly adhesively between dentin and the adhesive, or mixed adhesive-cohesively. SIGNIFICANCE: The bonding effectiveness of the glass-ionomer adhesive tested was affected by the area of intertubular dentin available for micro-mechanical retention through hybrid-layer formation. Removal of the smear layer improved the bond strength of the adhesive to dentin.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11445212     DOI: 10.1016/s0109-5641(01)00003-3

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  14 in total

1.  Effects of laser and acid etching and air abrasion on mineral content of dentin.

Authors:  Meral Arslan Malkoc; Serife Tuba Taşdemir; A Nilgun Ozturk; Bora Ozturk; Gizem Berk
Journal:  Lasers Med Sci       Date:  2010-01-19       Impact factor: 3.161

2.  Qualitative evaluation of hybrid layer formation using Er:YAG laser in QSP mode for tooth cavity preparations.

Authors:  Antonis Kallis; Kosmas Tolidis; Paris Gerasimou; Dimitrios Dionysopoulos
Journal:  Lasers Med Sci       Date:  2018-07-08       Impact factor: 3.161

3.  Microleakage in Class V cavities with self-etching adhesive system and conventional rotatory or laser Er,Cr:YSGG.

Authors:  K Trelles; J Arnabat; T España-Tost
Journal:  Laser Ther       Date:  2012-12-26

4.  Effects of dentin surface treatments on shear bond strength of glass-ionomer cements.

Authors:  Claudio Poggio; Riccardo Beltrami; Andrea Scribante; Marco Colombo; Marco Lombardini
Journal:  Ann Stomatol (Roma)       Date:  2014-03-31

5.  Primer application technique and remaining dentin thickness affected microtensile bond strength of contemporary dentin adhesives under simulated pulp pressure.

Authors:  Paphawee Somrit; Yanee Tantilertanant; Sirivimol Srisawasdi
Journal:  Clin Oral Investig       Date:  2022-09-16       Impact factor: 3.606

6.  Comparison of the Estimated Radiographic Remaining Dentine Thickness with the Actual Thickness Below the Deep Carious Lesions on the Posterior Teeth: An in vitro Study.

Authors:  Nouf Al Jhany; Banin Al Hawaj; Alanoud Al Hassan; Zhoor Al Semrani; Mohammed Al Bulowey; Shahzeb Ansari
Journal:  Eur Endod J       Date:  2019-11-26

7.  Effect of acid pre-conditioning and/or delayed light irradiation on enamel bond strength of three resin-modified glass ionomers.

Authors:  Maryam Khoroushi; Moeen Hosseini-Shirazi; Hojatolah Soleimani
Journal:  Dent Res J (Isfahan)       Date:  2013-05

8.  Micro-tensile bond strength of adhesives to pulp chamber dentin after irrigation with Ethylenediaminetetraacetic acid.

Authors:  C Barutcigil; H Arslan; E Ozcan; Ot Harorlı
Journal:  J Conserv Dent       Date:  2012-07

9.  Clinical effectiveness of contemporary dentin bonding agents.

Authors:  Jogikalmat Krithikadatta
Journal:  J Conserv Dent       Date:  2010-10

10.  The effect of the pre-conditioning step on the shear bond strength of nano-filled resin-modified glass-ionomer to dentin.

Authors:  Farid S El-Askary; Mohammed S Nassif
Journal:  Eur J Dent       Date:  2011-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.