Literature DB >> 11444519

Delivery systems of intensity-modulated radiotherapy using conventional multileaf collimators.

P Xia1, L J Verhey.   

Abstract

Intensity-modulated radiotherapy (IMRT) using conventional multileaf collimators (MLCs) has gained much attention in the radiation therapy community. To implement IMRT safely and efficiently, it is essential to understand the characteristics of MLCs, the associated delivery systems, and the limitations of each system when applied to IMRT. In this article, 3 major manufactured MLC collimators are reviewed, including the general descriptions such as the location of the MLC, whether or not it is single focused or double focused, the physical characteristics of leaves, the leaf movement restrictions, and the maximum achievable field size for IMRT delivery. MLC-based static and dynamic mechanisms are reviewed, and the delivery systems for these 3 collimators are described. Machine-related and patient plan-related quality assurance issues are discussed. Our conclusions are that MLC-based IMRT delivery is practical; however, extensive efforts are needed when IMRT is implemented in clinics.

Entities:  

Mesh:

Year:  2001        PMID: 11444519     DOI: 10.1016/s0958-3947(01)00060-7

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  6 in total

Review 1.  New developments in radiation therapy for head and neck cancer: intensity-modulated radiation therapy and hypoxia targeting.

Authors:  Nancy Y Lee; Quynh-Thu Le
Journal:  Semin Oncol       Date:  2008-06       Impact factor: 4.929

2.  Impact of dose rate on accuracy of intensity modulated radiation therapy plan delivery using the pretreatment portal dosimetry quality assurance and setting up the workflow at hospital levels.

Authors:  Karunakaran Kaviarasu; N Arunai Nambi Raj; K Krishna Murthy; A Ananda Giri Babu; Bhaskar Laxman Durga Prasad
Journal:  J Med Phys       Date:  2015 Oct-Dec

3.  Dosimetric effects of jaw tracking in step-and-shoot intensity-modulated radiation therapy.

Authors:  Sarah Joy; George Starkschall; Stephen Kry; Mohammed Salehpour; R Allen White; Steven H Lin; Peter Balter
Journal:  J Appl Clin Med Phys       Date:  2012-03-08       Impact factor: 2.102

4.  Verification of Dosimetric Commissioning Accuracy of Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Delivery using Task Group-119 Guidelines.

Authors:  Karunakaran Kaviarasu; N Arunai Nambi Raj; Misba Hamid; A Ananda Giri Babu; Lingampally Sreenivas; Kammari Krishna Murthy
Journal:  J Med Phys       Date:  2017 Oct-Dec

5.  Compensators: an alternative IMRT delivery technique.

Authors:  Sha X Chang; Timothy J Cullip; Katharin M Deschesne; Elizabeth P Miller; Julian G Rosenman
Journal:  J Appl Clin Med Phys       Date:  2004-07-01       Impact factor: 2.102

6.  Dosimetric characteristics of a cubic-block-piled compensator for intensity-modulated radiation therapy in the Pinnacle radiotherapy treatment planning system.

Authors:  Koji Sasaki; Yasunori Obata
Journal:  J Appl Clin Med Phys       Date:  2006-06-16       Impact factor: 2.102

  6 in total