Theoretical analysis of the effect of imperfect slice profiles on tagging schemes for pulsed arterial spin labeling MRI.

S D Keilholz-George1, J Knight-Scott, S S Berr.   

Abstract

Pulsed arterial spin labeling (ASL) techniques provide a noninvasive method of obtaining qualitative and quantitative perfusion images with MRI. ASL techniques employ inversion recovery and/or saturation recovery to induce perfusion weighting, and thus the performance of these techniques is dependent on the slice profiles of the inversion or saturation pulses. This article systematically examines through simulations the effects of slice profile imperfections on the perfusion signal for nine labeling schemes, including FAIR, FAIRER, and EST (UNFAIR). Each sequence is evaluated for quantitative accuracy, suppression of stationary signal, and magnitude of perfusion signal. Perfusion effects are modeled from a modified Bloch equation and experimentally determined slice profiles. The results show that FAIR, FAIRER, and EST have excellent tissue suppression. The magnitude of the perfusion signal is comparable for FAIR and FAIRER, with EST providing a slightly weaker signal. For quantitative measurements, all three methods underestimate the perfusion signal by more than 20%. Of the additional six ASL techniques examined, only one performed well in this model. This method, which combines inversion and saturation recovery, yields improved signal accuracy (<15% difference from the theoretical value) and tissue suppression similar to that of FAIR and its variants, but has only half the signal. Magn Reson Med 46:141-148, 2001. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2001        PMID: 11443720     DOI: 10.1002/mrm.1169

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  Characterizing pulmonary blood flow distribution measured using arterial spin labeling.

Authors:  A Cortney Henderson; G Kim Prisk; David L Levin; Susan R Hopkins; Richard B Buxton
Journal:  NMR Biomed       Date:  2009-12       Impact factor: 4.044

2.  Arterial spin-labeling MR imaging measurements of timing parameters in patients with a carotid artery occlusion.

Authors:  R P H Bokkers; P J van Laar; K C C van de Ven; L J Kapelle; C J M Klijn; J Hendrikse
Journal:  AJNR Am J Neuroradiol       Date:  2008-08-13       Impact factor: 3.825

3.  Improved perfusion-weighted MRI by a novel double inversion with proximal labeling of both tagged and control acquisitions.

Authors:  Geon-Ho Jahng; Xiao-Ping Zhu; Gerald B Matson; Michael W Weiner; Norbert Schuff
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.