Literature DB >> 11443719

Fast T(1) mapping with volume coverage.

S Steinhoff1, M Zaitsev, K Zilles, N J Shah.   

Abstract

Four different sequences which enable high-resolution, multislice T(1) relaxation-time mapping are presented. All these sequences are based on the Look-Locker method with differences arising from the use of either a saturation-recovery or inversion-recovery module prior to data acquisition with a full k-space or banded k-space acquisition scheme. The methods were implemented on a standard clinical scanner and the accuracy of the T(1) results was evaluated against spectroscopic measurements. The accuracy of the T(1) maps validated by phantom imaging measurements is around 1% for species which relax with T(1) times that mimic gray/white matter (T(1) < or = 1000 ms). Additionally, the inherent multislice, multipoint capability of the methods is demonstrated. Finally, in vivo results of the human brain obtained using the faster method are presented. The fastest data acquisition was achieved with a saturation-recovery, banded k-space method where k-space was divided into three segments; an overall acquisition time of around 5 min (for species with T(1) < or = 1 sec) was achieved for a T(1) map which can, in principle, provide whole-brain coverage with a matrix size of 256 x 256 at multiple time-points. Magn Reson Med 46:131-140, 2001. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11443719     DOI: 10.1002/mrm.1168

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  Quantification of blood-to-brain transfer rate in multiple sclerosis.

Authors:  Saeid Taheri; Gary A Rosenberg; Corey Ford
Journal:  Mult Scler Relat Disord       Date:  2012-10-24       Impact factor: 4.339

2.  Measurement of kinetic parameters in skeletal muscle by magnetic resonance imaging with an intravascular agent.

Authors:  Anthony Z Faranesh; Dara L Kraitchman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

3.  Magnetic field dependence of the distribution of NMR relaxation times in the living human brain.

Authors:  A M Oros-Peusquens; M Laurila; N J Shah
Journal:  MAGMA       Date:  2008-03-13       Impact factor: 2.310

4.  Quantitative measurement of blood-brain barrier permeability in human using dynamic contrast-enhanced MRI with fast T1 mapping.

Authors:  Saeid Taheri; Charles Gasparovic; Nadim Jon Shah; Gary A Rosenberg
Journal:  Magn Reson Med       Date:  2010-12-13       Impact factor: 4.668

5.  Fast and high-resolution quantitative mapping of tissue water content with full brain coverage for clinically-driven studies.

Authors:  Mohammad Sabati; Andrew A Maudsley
Journal:  Magn Reson Imaging       Date:  2013-09-17       Impact factor: 2.546

Review 6.  Current and future applications of magnetic resonance imaging and spectroscopy of the brain in hepatic encephalopathy.

Authors:  V-P Bob Grover; M-Alex Dresner; Daniel-M Forton; Serena Counsell; David-J Larkman; Nayna Patel; Howard-C Thomas; Simon-D Taylor-Robinson
Journal:  World J Gastroenterol       Date:  2006-05-21       Impact factor: 5.742

7.  MPnRAGE: A technique to simultaneously acquire hundreds of differently contrasted MPRAGE images with applications to quantitative T1 mapping.

Authors:  Steven Kecskemeti; Alexey Samsonov; Samuel A Hurley; Douglas C Dean; Aaron Field; Andrew L Alexander
Journal:  Magn Reson Med       Date:  2015-04-17       Impact factor: 4.668

8.  Rapid volumetric T1 mapping of the abdomen using three-dimensional through-time spiral GRAPPA.

Authors:  Yong Chen; Gregory R Lee; Gunhild Aandal; Chaitra Badve; Katherine L Wright; Mark A Griswold; Nicole Seiberlich; Vikas Gulani
Journal:  Magn Reson Med       Date:  2015-05-18       Impact factor: 4.668

9.  On the selection of sampling points for myocardial T1 mapping.

Authors:  Mehmet Akçakaya; Sebastian Weingärtner; Sébastien Roujol; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-05-06       Impact factor: 4.668

10.  Improve myocardial T1 measurement in rats with a new regression model: application to myocardial infarction and beyond.

Authors:  Haosen Zhang; Qing Ye; Jie Zheng; Erik B Schelbert; T Kevin Hitchens; Chien Ho
Journal:  Magn Reson Med       Date:  2013-10-18       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.