Literature DB >> 11443391

Intracardiac ultrasound assessment of atrial septal defect: comparison with transthoracic echocardiographic, angiocardiographic, and balloon-sizing measurements.

S L Jan1, B Hwang , P C Lee, Y C Fu, P S Chiu, C S Chi.   

Abstract

PURPOSE: Accurate evaluation of the size, location and adjacent structure of an atrial septal defect (ASD) is very important in the selection of patients for further management. We directly compared the utility of transthoracic echocardiography, angiocardiography, balloon sizing, and intracardiac ultrasound (ICUS) in the detection of ASD.
METHODS: Twenty-one children underwent an ICUS study of ASD after routine clinical and laboratory studies. All patients had received transthoracic echocardiography (TTE), cardiac catheterization, cineangiography, and balloon sizing before the ICUS to evaluate the ASD.
RESULTS: There was a significant correlation between the ICUS-derived ASD diameter and the other methods (p < 0.001). The balloon-sizing diameter was estimated by the equation: TTE diameter x 1.09 + 3.9 mm. There was a good correlation between the predicted and measured balloon-sizing diameter (r = 0.963; p < 0.001).
CONCLUSION: It is worthwhile spending a few minutes to perform ICUS during cardiac catheterization since it will provide more detailed information on and high resolution images of atrial septal morphology, especially for patients undergoing transcatheter closure by device.

Entities:  

Mesh:

Year:  2001        PMID: 11443391     DOI: 10.1007/s002700000397

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  6 in total

Review 1.  Transoesophageal echocardiography during interventional cardiac catheterisation in congenital heart disease.

Authors:  M L Rigby
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

2.  Assessment of atrial septum morphology by live three-dimensional echocardiography.

Authors:  Lingyun Fang; Mingxing Xie; Xinfang Wang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2007-12

3.  Intracardiac echocardiography: gross anatomy and magnetic resonance correlations and validations.

Authors:  Mario Zanchetta; Gianluca Rigatelli; Luigi Pedon; Marco Zennaro; Kostantinos Dimopoulous; Eustaquio Onorato; Carla Frescura; Pietro Maiolino; Gaetano Thiene; Annalisa Angelini
Journal:  Int J Cardiovasc Imaging       Date:  2005-08       Impact factor: 2.357

4.  Predictors of successful transcatheter closure of atrial septal defect by cardiac magnetic resonance imaging.

Authors:  K Durongpisitkul; N L Tang; J Soongswang; D Laohaprasitiporn; A Nanal
Journal:  Pediatr Cardiol       Date:  2003-12-15       Impact factor: 1.655

5.  Transjugular intravascular ultrasound for the evaluation of hepatic vasculature and parenchyma in patients with chronic liver disease.

Authors:  Andrea De Gottardi; Pierre-Frédéric Keller; Antoine Hadengue; Emile Giostra; Laurent Spahr
Journal:  BMC Res Notes       Date:  2012-01-27

6.  A comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect.

Authors:  Alimohammad Hajizeinali; Hakimeh Sadeghian; Mehrnaz Rezvanfard; Mohammad Alidoosti; Arezoo Zoroufian; Marat A Volman
Journal:  Cardiovasc J Afr       Date:  2013-06       Impact factor: 1.167

  6 in total