Literature DB >> 11442731

Subgingival polishing with a teflon-coated sonic scaler insert in comparison to conventional instruments as assessed on extracted teeth (II). Subgingival roughness.

T Kocher1, M Rosin, N Langenbeck, O Bernhardt.   

Abstract

AIM: To assess the root surface roughness and topography on extracted teeth using different instruments.
MATERIAL AND METHODS: In the present study, laser profilometry was used to examine the 3-D roughness values Ra and Rz and topography of root surfaces of periodontally-involved teeth instrumented in vivo with curette, conventional ultrasonic device, conventional or teflon-coated sonic scaler insert, or the Periotor instrument (12 teeth per instrument type), and compare these with uninstrumented cementum surfaces.
RESULTS: The roughness values Ra and Rz of the roots treated with the different instruments showed a similar pattern: curettes and the Periotor instrument produced the smoothest surfaces (Ra about 1.5 microm, Rz 30 microm); the 4 other instruments created similar Ra values of approximately 2-3 microm and Rz roughness of about 50-70 microm, which equals the untreated root surface. For Ra, the difference between the curette or the Periotor instrument and the teflon-coated sonic insert or ultrasonic insert was significant, and for Rz, a significant difference was found between the curette or the Periotor instrument and ultrasonic insert. As opposed to surfaces debrided with the Periotor and teflon-coated sonic scaler, it appears that hand instruments markedly reconfigure surfaces.
CONCLUSION: The lowest root-surface roughness values were obtained with hand instruments. The teflon tubing on the sonic scaler insert effected no change of topography or roughness as compared to uninstrumented, control surfaces. However, it must be pointed out that hard-tissue removal was not investigated.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11442731     DOI: 10.1034/j.1600-051x.2001.280802.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  4 in total

1.  Comparative study on the effect of ultrasonic instruments on the root surface in vivo.

Authors:  Fábio André Santos; Márcia Thaís Pochapski; Paola Cristina Leal; Patrícia Panizzi Gimenes-Sakima; Elcio Marcantonio
Journal:  Clin Oral Investig       Date:  2007-12-04       Impact factor: 3.573

2.  Effects of Root Debridement With Hand Curettes and Er:YAG Laser on Chemical Properties and Ultrastructure of Periodontally-Diseased Root Surfaces Using Spectroscopy and Scanning Electron Microscopy.

Authors:  Reza Amid; Gholam Ali Gholami; Masoud Mojahedi; Maryam Aghalou; Mohsen Gholami; Mahdieh Mirakhori
Journal:  J Lasers Med Sci       Date:  2017-03-28

3.  Analysis of the effects of air polishing powders containing sodium bicarbonate and glycine on human teeth.

Authors:  Julia Bühler; Fredy Schmidli; Roland Weiger; Clemens Walter
Journal:  Clin Oral Investig       Date:  2014-09-21       Impact factor: 3.573

4.  In vitro evaluation of surface roughness, adhesion of periodontal ligament fibroblasts, and Streptococcus gordonii following root instrumentation with Gracey curettes and subsequent polishing with diamond-coated curettes.

Authors:  Sigrun Eick; Philip Bender; Simon Flury; Adrian Lussi; Anton Sculean
Journal:  Clin Oral Investig       Date:  2012-04-17       Impact factor: 3.573

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.